Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 103

1.

Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope.

Gupta K, Girdhar KK, Anand R, Majgi SM, Gupta SP, Gupta PB.

Indian J Anaesth. 2012 Jul;56(4):353-8. doi: 10.4103/0019-5049.100816.

PMID:
23087457
[PubMed]
Free PMC Article
2.

The circulatory responses to fibreoptic intubation: a comparison of oral and nasal routes.

Xue FS, Li CW, Sun HT, Liu KP, Zhang GH, Xu YC, Liu Y, Yu L.

Anaesthesia. 2006 Jul;61(7):639-45.

PMID:
16792608
[PubMed - indexed for MEDLINE]
3.

Comparison of haemodynamic responses to orotracheal intubation with GlideScope videolaryngoscope and fibreoptic bronchoscope.

Xue FS, Zhang GH, Li XY, Sun HT, Li P, Sun HY, Xu YC, Liu Y.

Eur J Anaesthesiol. 2006 Jun;23(6):522-6. Epub 2006 Mar 1.

PMID:
16507195
[PubMed - indexed for MEDLINE]
4.

Blood pressure and heart rate changes during intubation: a comparison of direct laryngoscopy and a fibreoptic method.

Xue FS, Zhang GH, Sun HY, Li CW, Li P, Sun HT, Liu KP, Xu YC, Liu Y.

Anaesthesia. 2006 May;61(5):444-8.

PMID:
16674618
[PubMed - indexed for MEDLINE]
5.

[Comparison of cardiovascular responses between orotracheal and nasotracheal intubation with the aid of GlideScope video laryngoscope].

Liu HP, Xue FS, Li XY, Xu YC, Yang QY.

Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2008 Jul;20(7):405-8. Chinese.

PMID:
18611338
[PubMed - indexed for MEDLINE]
Free Article
6.

[Comparison of hemodynamic responses to nasotracheal intubations with Glide Scope video-laryngoscope, Macintosh direct laryngoscope, and fiberoptic bronchoscope].

Li XY, Xue FS, Sun L, Xu YC, Liu Y, Zhang GH, Li CW, Liu KP, Sun HT.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2007 Feb;29(1):117-23. Chinese.

PMID:
17380681
[PubMed - indexed for MEDLINE]
Free Article
7.

Blood pressure and heart rate changes during fibreoptic orotracheal intubation: a comparison of children and adults.

Xue FS, Zhang GH, Sun HT, Li CW, Liu KP, Xu YC, Liu Y.

Eur J Anaesthesiol. 2007 Jan;24(1):39-45. Epub 2006 Jun 20.

PMID:
16784551
[PubMed - indexed for MEDLINE]
8.

[Hemodynamic responses to orotracheal intubation with fiberoptic bronchoscope and direct laryngoscope in children].

Sun HT, Xue FS, Zhang GH, Li CW, Li P, Liu KP.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2005 Dec;27(6):712-7. Chinese.

PMID:
16447644
[PubMed - indexed for MEDLINE]
9.

Hemodynamic responses to tracheal intubation with the Glidescope videolaryngoscope: a comparison of oral and nasal routes.

Xue FS, Xu YC, Liu QJ, Yang QY, Liu Y, Liao X, Li XY.

Acta Anaesthesiol Taiwan. 2008 Mar;46(1):8-15.

PMID:
18390395
[PubMed - indexed for MEDLINE]
10.

A comparative study of hemodynamic responses to orotracheal intubation with fiberoptic bronchoscope and laryngoscope in children.

Xue FS, Zhang GH, Sun HT, Li CW, Li P, Liu KP, Xu YC, Liu Y, Liu J.

Paediatr Anaesth. 2006 Jul;16(7):743-7.

PMID:
16879516
[PubMed - indexed for MEDLINE]
11.

[Hemodynamic responses to orotracheal intubation with upsherscope or Macintosh direct laryngoscope].

Yang D, Deng XM, Wei LX, Luo MP, Liu JH, Tang GZ, Xu KL.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2007 Oct;29(5):656-60. Chinese.

PMID:
18051724
[PubMed - indexed for MEDLINE]
Free Article
12.

Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope.

Xue FS, Li XY, Liu QJ, Liu HP, Yang QY, Xu YC, Liao X, Liu Y.

Chin Med J (Engl). 2008 Jul 20;121(14):1290-6.

PMID:
18713550
[PubMed - indexed for MEDLINE]
Free Article
13.

[Comparison of hemodynamic responses to orotracheal intubation with shikani laryngoscope or macintosh direct laryngoscope].

Zhao SB, Jia NG, Liu KP, Li CH, Zhang YJ, Han L, Xue FS.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2010 Jun;32(3):303-9. doi: 10.3881/j.issn.1000-503X.2010.03.014. Chinese.

PMID:
20602884
[PubMed - indexed for MEDLINE]
Free Article
14.

[Comparison of hemodynamic responses to orotracheal intubation between using GlideScope videolaryngoscope and fiberoptic bronchoscope].

Zhang GH, Xue FS, Li CW, Sun HY, Li XY, Sun HT, Liu KP.

Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2006 Jun;28(3):406-9. Chinese.

PMID:
16900645
[PubMed - indexed for MEDLINE]
Free Article
15.

[Fiber optic intubation using a modified laryngeal mask. Report of experiences with use in 105 patients].

Tessmann R, Wittenbeck J, Lüpke U, Marx A.

Anasthesiol Intensivmed Notfallmed Schmerzther. 1997 Mar;32(3):164-8. German.

PMID:
9190164
[PubMed - indexed for MEDLINE]
16.

Teaching fibreoptic intubation in anaesthetised patients.

Schaefer HG, Marsch SC, Keller HL, Strebel S, Anselmi L, Drewe J.

Anaesthesia. 1994 Apr;49(4):331-4.

PMID:
8179144
[PubMed - indexed for MEDLINE]
17.

Comparative study of hemodynamic responses to orotracheal intubation with intubating laryngeal mask airway.

Zhang GH, Xue FS, Sun HY, Li CW, Sun HT, Li P, Liu KP.

Chin Med J (Engl). 2006 Jun 5;119(11):899-904.

PMID:
16780768
[PubMed - indexed for MEDLINE]
Free Article
18.

Heart rate and arterial pressure changes during fibreoptic tracheal intubation under general anaesthesia.

Smith JE.

Anaesthesia. 1988 Aug;43(8):629-32.

PMID:
3421452
[PubMed - indexed for MEDLINE]
19.

Comparison of bolus remifentanil versus bolus fentanyl for blunting cardiovascular intubation responses in children: a randomized, double-blind study.

Yang QY, Xue FS, Liao X, Liu HP, Luo MP, Xu YC, Liu Y, Zhang YM.

Chin Med J (Engl). 2009 Jan 5;122(1):44-50.

PMID:
19187616
[PubMed - indexed for MEDLINE]
Free Article
20.

Comparison of a rigid laryngoscope with the ultrathin fibreoptic laryngoscope for tracheal intubation in infants.

Roth AG, Wheeler M, Stevenson GW, Hall SC.

Can J Anaesth. 1994 Nov;41(11):1069-73.

PMID:
7828254
[PubMed - indexed for MEDLINE]

Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk