Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 126

Similar articles for PubMed (Select 22733713)

1.

A gentamicin-releasing coating for cementless hip prostheses-Longitudinal evaluation of efficacy using in vitro bio-optical imaging and its wide-spectrum antibacterial efficacy.

Neut D, Dijkstra RJ, Thompson JI, van der Mei HC, Busscher HJ.

J Biomed Mater Res A. 2012 Dec;100(12):3220-6. doi: 10.1002/jbm.a.34258. Epub 2012 Jun 26.

PMID:
22733713
2.

Antibacterial efficacy of a new gentamicin-coating for cementless prostheses compared to gentamicin-loaded bone cement.

Neut D, Dijkstra RJ, Thompson JI, van der Mei HC, Busscher HJ.

J Orthop Res. 2011 Nov;29(11):1654-61. doi: 10.1002/jor.21433. Epub 2011 Apr 13.

PMID:
21491478
3.

A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses.

Neut D, Dijkstra RJ, Thompson JI, Kavanagh C, van der Mei HC, Busscher HJ.

Eur Cell Mater. 2015 Jan 2;29:42-55; discussion 55-6.

4.

Antimicrobial activity of gentamicin palmitate against high concentrations of Staphylococcus aureus.

Kittinger C, Marth E, Windhager R, Weinberg AM, Zarfel G, Baumert R, Felisch S, Kuehn KD.

J Mater Sci Mater Med. 2011 Jun;22(6):1447-53. doi: 10.1007/s10856-011-4333-4. Epub 2011 May 10.

PMID:
21556977
5.

The effects of combined gentamicin-hydroxyapatite coating for cementless joint prostheses on the reduction of infection rates in a rabbit infection prophylaxis model.

Alt V, Bitschnau A, Osterling J, Sewing A, Meyer C, Kraus R, Meissner SA, Wenisch S, Domann E, Schnettler R.

Biomaterials. 2006 Sep;27(26):4627-34. Epub 2006 May 19.

PMID:
16712926
6.

Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro.

Li LL, Wang LM, Xu Y, Lv LX.

Arch Orthop Trauma Surg. 2012 Jun;132(6):897-903. doi: 10.1007/s00402-012-1490-y. Epub 2012 Feb 29.

PMID:
22373914
7.

In vitro inhibition of coagulase-negative staphylococci by vancomycin/aminoglycoside-loaded cement spacers.

Streuli JC, Exner GU, Reize CL, Merkofer C, Scott CP, Zbinden R.

Infection. 2006 Apr;34(2):81-6.

PMID:
16703297
8.

[Elution kinetics and antimicrobial effects of gentamicin- and clindamycin-loaded bone cements in vitro].

Schiefer UR, Heiss C, Dingeldein E, Wenisch S, Schnettler R, Kilian O.

Z Orthop Unfall. 2008 Jan-Feb;146(1):92-8. doi: 10.1055/s-2007-989301. German.

PMID:
18324589
9.

Electrochemically deposited gentamicin-loaded calcium phosphate coatings for bone tissue integration.

Altomare L, Visai L, Bloise N, Arciola CR, Ulivi L, Candiani G, Cigada A, Chiesa R, De Nardo L.

Int J Artif Organs. 2012 Oct;35(10):876-83. doi: 10.5301/ijao.5000162.

PMID:
23138703
10.

Biological and antibacterial properties of plasma sprayed wollastonite coatings grafting gentamicin loaded collagen.

Li B, Liu X, Cao C, Dong Y, Wang Z, Ding C.

J Biomed Mater Res A. 2008 Oct;87(1):84-90.

PMID:
18085657
11.

Effect on infection resistance of a local antiseptic and antibiotic coating on osteosynthesis implants: an in vitro and in vivo study.

Kälicke T, Schierholz J, Schlegel U, Frangen TM, Köller M, Printzen G, Seybold D, Klöckner S, Muhr G, Arens S.

J Orthop Res. 2006 Aug;24(8):1622-40.

PMID:
16779814
12.

[In vitro comparison of antibacterial properties of plasma sprayed wollastonite coatings loading silver and gentamicin].

Dong YQ, Li BE, Liu XY, Feng Y, Cao C.

Zhonghua Wai Ke Za Zhi. 2008 Dec 15;46(24):1923-6. Chinese.

PMID:
19134389
13.

Gentamicin-loaded strontium-containing hydroxyapatite bioactive bone cement--an efficient bioactive antibiotic drug delivery system.

Liu WC, Wong CT, Fong MK, Cheung WS, Kao RY, Luk KD, Lu WW.

J Biomed Mater Res B Appl Biomater. 2010 Nov;95(2):397-406. doi: 10.1002/jbm.b.31730.

PMID:
20878924
14.

Antimicrobial efficacy of gentamicin-loaded acrylic bone cements with fusidic acid or clindamycin added.

Neut D, Hendriks JG, van Horn JR, Kowalski RS, van der Mei HC, Busscher HJ.

J Orthop Res. 2006 Feb;24(2):291-9.

PMID:
16435362
15.

In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.

Nakahara I, Takao M, Bandoh S, Bertollo N, Walsh WR, Sugano N.

J Orthop Res. 2013 Mar;31(3):485-92. doi: 10.1002/jor.22251. Epub 2012 Oct 23.

PMID:
23097319
16.

[In vitro evaluation of gentamicin and teicoplanin release from cancellous human bone].

Kazimoğlu C, Karapinar H, Sener M, Afşar I, Sener AG, Akgün U.

Acta Orthop Traumatol Turc. 2008 Jan-Feb;42(1):64-9. Turkish.

PMID:
18354280
17.

In vitro testing of gentamicin-vancomycin loaded bone cement to prevent prosthetic joint infection.

Gallo J, Kolár M, Florschütz AV, Novotný R, Pantůcek R, Kesselová M.

Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2005 Jun;149(1):153-8.

18.

In vitro testing of chitosan in gentamicin-loaded bone cement: no antimicrobial effect and reduced mechanical performance.

Dunne N, Buchanan F, Hill J, Newe C, Tunney M, Brady A, Walker G.

Acta Orthop. 2008 Dec;79(6):851-60. doi: 10.1080/17453670810016957.

PMID:
19085505
19.

Biocompatibility and antibacterial activity of plasma sprayed titania coating grafting collagen and gentamicin.

Li B, Liu X, Cao C, Ding C.

J Biomed Mater Res A. 2007 Dec 15;83(4):923-30.

PMID:
17567859
20.

Effect of bacterial media on the evaluation of the antibacterial activity of a biomaterial containing inorganic antibacterial reagents or antibiotics.

Ando Y, Miyamoto H, Noda I, Miyaji F, Shimazaki T, Yonekura Y, Miyazaki M, Mawatari M, Hotokebuchi T.

Biocontrol Sci. 2010 Mar;15(1):15-9.

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk