Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 120

Similar articles for PubMed (Select 22692747)

1.

Cross-platform analysis of HIV-1 RNA data generated by a multicenter assay validation study with wide geographic representation.

Jennings C, Harty B, Granger S, Wager C, Crump JA, Fiscus SA, Bremer JW.

J Clin Microbiol. 2012 Aug;50(8):2737-47. doi: 10.1128/JCM.00578-12. Epub 2012 Jun 12.

2.

High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.

Karasi JC, Dziezuk F, Quennery L, Förster S, Reischl U, Colucci G, Schoener D, Seguin-Devaux C, Schmit JC.

J Clin Virol. 2011 Nov;52(3):181-6. doi: 10.1016/j.jcv.2011.07.002. Epub 2011 Aug 3.

PMID:
21813320
3.

Comparative evaluation of the Abbott HIV-1 RealTime™ assay with the Standard Roche COBAS® Amplicor™ HIV-1 Monitor® Test, v1.5 for determining HIV-1 RNA levels in plasma specimens from Pune, India.

Khopkar P, Mallav V, Chidrawar S, Kulkarni S.

J Virol Methods. 2013 Jul;191(1):82-7. doi: 10.1016/j.jviromet.2013.03.021. Epub 2013 Apr 12.

PMID:
23588214
4.

Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece.

Katsoulidou A, Rokka C, Issaris C, Haida C, Tzannis K, Sypsa V, Detsika M, Paraskevis D, Hatzakis A.

Virol J. 2011 Jan 11;8:10. doi: 10.1186/1743-422X-8-10.

5.

Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test and identification of rare polymorphisms potentially affecting assay performance.

Pyne MT, Brown KL, Hillyard DR.

J Clin Microbiol. 2010 Aug;48(8):2852-8. doi: 10.1128/JCM.00776-10. Epub 2010 Jun 23.

6.

Performance evaluation of the new Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 for quantification of human immunodeficiency virus type 1 RNA.

Pas S, Rossen JW, Schoener D, Thamke D, Pettersson A, Babiel R, Schutten M.

J Clin Microbiol. 2010 Apr;48(4):1195-200. doi: 10.1128/JCM.01832-09. Epub 2010 Feb 17.

8.
10.

Comparative RNA quantification of HIV-1 group M and non-M with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR assays.

Sire JM, Vray M, Merzouk M, Plantier JC, Pavie J, Maylin S, Timsit J, Lascoux-Combe C, Molina JM, Simon F, Delaugerre C.

J Acquir Immune Defic Syndr. 2011 Mar 1;56(3):239-43. doi: 10.1097/QAI.0b013e3182099891.

PMID:
21164353
11.

Analytical sensitivity of three real-time PCR assays for measuring subtype B HIV-1 RNA.

Sauné K, Delaugerre C, Raymond S, Nicot F, Boineau J, Pasquier C, Izopet J.

J Clin Virol. 2013 May;57(1):80-3. doi: 10.1016/j.jcv.2012.12.017. Epub 2013 Jan 11.

PMID:
23317874
12.

Comparison of 3 nucleic acid isolation methods for the quantification of HIV-1 RNA by Cobas Taqman real-time polymerase chain reaction system.

Alp A, Hascelik G.

Diagn Microbiol Infect Dis. 2009 Apr;63(4):365-71. doi: 10.1016/j.diagmicrobio.2008.12.014. Epub 2009 Feb 18.

PMID:
19232859
14.

Large-scale comparison of Roche Cobas AmpliPrep/Cobas TaqMan and Abbott RealTime HIV assays.

Pyne MT, Wilson A, Hillyard DR.

J Virol Methods. 2012 Sep;184(1-2):106-8. doi: 10.1016/j.jviromet.2012.05.007. Epub 2012 May 17.

PMID:
22609889
15.

Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals.

Taylor N, Schmid I, Egle A, Greil R, Patsch W, Oberkofler H.

Antivir Ther. 2009;14(8):1189-93. doi: 10.3851/IMP1427.

PMID:
20032549
16.

Comparison of the RealTime HIV-1, COBAS TaqMan 48 v1.0, Easy Q v1.2, and Versant v3.0 assays for determination of HIV-1 viral loads in a cohort of Canadian patients with diverse HIV subtype infections.

Church D, Gregson D, Lloyd T, Klein M, Beckthold B, Laupland K, Gill MJ.

J Clin Microbiol. 2011 Jan;49(1):118-24. doi: 10.1128/JCM.00685-10. Epub 2010 Nov 17.

17.

Comparison of Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0) with other real-time PCR assays in HIV-1 monitoring and follow-up of low-level viral loads.

Wojewoda CM, Spahlinger T, Harmon ML, Schnellinger B, Li Q, Dejelo C, Schmotzer C, Zhou L.

J Virol Methods. 2013 Jan;187(1):1-5. doi: 10.1016/j.jviromet.2012.10.004. Epub 2012 Oct 22.

PMID:
23098667
18.

Comparative frequencies of HIV low-level viremia between real-time viral load assays at clinically relevant thresholds.

Do T, Duncan J, Butcher A, Liegler T.

J Clin Virol. 2011 Dec;52 Suppl 1:S83-9. doi: 10.1016/j.jcv.2011.09.022. Epub 2011 Oct 12.

PMID:
21995930
19.

Comparison of the Abbott realtime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs.

Sloma CR, Germer JJ, Gerads TM, Mandrekar JN, Mitchell PS, Yao JD.

J Clin Microbiol. 2009 Apr;47(4):889-95. doi: 10.1128/JCM.02231-08. Epub 2009 Feb 4.

20.

Evaluation of the QIAsymphony™ SP and Artus™ RealTime extraction-quantification systems for measuring HIV-1 virus load.

Sandres-Sauné K, Raymond S, Nicot F, Boineau J, Pasquier C, Izopet J.

J Clin Virol. 2011 Dec;52(4):349-52. doi: 10.1016/j.jcv.2011.08.026. Epub 2011 Sep 23.

PMID:
21945406
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk