Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 130

1.

Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

Silber HA, Trost JC, Johnston PV, Maughan WL, Wang NY, Kasper EK, Aversano TR, Bush DE.

Am J Physiol Heart Circ Physiol. 2012 May 15;302(10):H2043-7. doi: 10.1152/ajpheart.00609.2011. Epub 2012 Mar 2.

2.

A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis.

Galiatsatos P, Parakh K, Monti J, Thavarajah S, Aneke-Ogbu H, Watson A, Kim D, Wang NY, Shafi T, Silber HA.

BMC Nephrol. 2015 Aug 14;16:138. doi: 10.1186/s12882-015-0135-0.

3.

Noninvasive assessment of left ventricular end-diastolic pressure by the response of the transmitral a-wave velocity to a standardized Valsalva maneuver.

Schwammenthal E, Popescu BA, Popescu AC, Di Segni E, Kaplinsky E, Rabinowitz B, Guetta V, Rath S, Feinberg MS.

Am J Cardiol. 2000 Jul 15;86(2):169-74.

PMID:
10913478
4.

Pulse pressure response to the strain of the valsalva maneuver in humans with preserved systolic function.

H├ębert JL, Coirault C, Zamani K, Fontaine G, Lecarpentier Y, Chemla D.

J Appl Physiol (1985). 1998 Sep;85(3):817-23.

5.

Impedance cardiographic measurement of the physiological response to the Valsalva manoeuvre.

Patterson RP, Zhang J.

Med Biol Eng Comput. 2003 Jan;41(1):40-3.

PMID:
12572746
6.

Determination of aortic valve opening time and left ventricular peak filling rate from the peripheral pulse amplitude in patients with ectopic beats.

Zheng D, Allen J, Murray A.

Physiol Meas. 2008 Dec;29(12):1411-9. doi: 10.1088/0967-3334/29/12/005. Epub 2008 Oct 30.

PMID:
18974441
7.

Tachycardia during the valsalva maneuver: a sign of normal diastolic filling pressures.

Maniu CV, Nishimura RA, Tajik AJ.

J Am Soc Echocardiogr. 2004 Jun;17(6):634-7.

PMID:
15163934
8.

Operating characteristics of the Finapress system to predict elevated left ventricular filling pressure.

Gillard C, Henuzet C, Lallemand J, Moscariello A, Guillaume M, Van Meerhaeghe A.

Clin Cardiol. 2006 Mar;29(3):107-11.

9.
10.

Simultaneous beat-by-beat investigation of the effects of the Valsalva maneuver on left and right ventricular filling and the possible mechanism.

Wang Z, Yuan LJ, Cao TS, Yang Y, Duan YY, Xing CY.

PLoS One. 2013;8(1):e53917. doi: 10.1371/journal.pone.0053917. Epub 2013 Jan 14.

11.

The mechanics of left ventricular filling during the strain phase of the valsalva maneuver in healthy subjects.

Zhang XY, Cao TS, Yuan LJ.

Am J Med Sci. 2013 Sep;346(3):187-9. doi: 10.1097/MAJ.0b013e31826af7de.

PMID:
23114199
12.

Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time.

Li Y, Wang Z, Zhang L, Yang X, Song J.

Australas Phys Eng Sci Med. 2014 Jun;37(2):367-76. doi: 10.1007/s13246-014-0269-6. Epub 2014 Apr 11.

PMID:
24722801
13.

Evaluation of a noninvasive system for determining left ventricular filling pressure.

Sharma GV, Woods PA, Lambrew CT, Berg CM, Pietro DA, Rocco TP, Welt FW, Sacchetti P, McIntyre KM.

Arch Intern Med. 2002 Oct 14;162(18):2084-8.

PMID:
12374516
14.

Accurate detection of elevated left ventricular filling pressure by a simplified bedside application of the Valsalva maneuver.

Schmidt DE, Shah PK.

Am J Cardiol. 1993 Feb 15;71(5):462-5. No abstract available.

PMID:
8430644
15.
16.

Hybrid cardiopulmonary model for analysis of valsalva maneuver with radial artery pulse.

Hemalatha K, Suganthi L, Manivannan M.

Ann Biomed Eng. 2010 Oct;38(10):3151-61. doi: 10.1007/s10439-010-0069-4. Epub 2010 May 25.

PMID:
20499184
17.

Changes in left ventricular ejection time and pulse transit time derived from finger photoplethysmogram and electrocardiogram during moderate haemorrhage.

Middleton PM, Chan GS, O'Lone E, Steel E, Carroll R, Celler BG, Lovell NH.

Clin Physiol Funct Imaging. 2009 May;29(3):163-9. doi: 10.1111/j.1475-097X.2008.00843.x. Epub 2009 Jan 22.

PMID:
19170720
18.

Respiration-induced changes in tissue blood volume distal to occluded artery, measured by photoplethysmography.

Nitzan M, Faib I, Friedman H.

J Biomed Opt. 2006 Jul-Aug;11(4):040506.

PMID:
16965128
19.
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk