Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 1829

1.

Continuous glucose monitoring systems for type 1 diabetes mellitus.

Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJ.

Cochrane Database Syst Rev. 2012 Jan 18;1:CD008101. doi: 10.1002/14651858.CD008101.pub2. Review.

PMID:
22258980
[PubMed - indexed for MEDLINE]
2.

Continuous Subcutaneous Insulin Infusion (CSII) Pumps for Type 1 and Type 2 Adult Diabetic Populations: An Evidence-Based Analysis.

Health Quality Ontario.

Ont Health Technol Assess Ser. 2009;9(20):1-58. Epub 2009 Oct 1.

PMID:
23074525
[PubMed]
Free PMC Article
3.

Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin.

Malanda UL, Welschen LM, Riphagen II, Dekker JM, Nijpels G, Bot SD.

Cochrane Database Syst Rev. 2012 Jan 18;1:CD005060. doi: 10.1002/14651858.CD005060.pub3. Review.

PMID:
22258959
[PubMed - indexed for MEDLINE]
4.

Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus.

Fullerton B, Jeitler K, Seitz M, Horvath K, Berghold A, Siebenhofer A.

Cochrane Database Syst Rev. 2014 Feb 14;2:CD009122. doi: 10.1002/14651858.CD009122.pub2. Review.

PMID:
24526393
[PubMed - indexed for MEDLINE]
5.

Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis.

Yeh HC, Brown TT, Maruthur N, Ranasinghe P, Berger Z, Suh YD, Wilson LM, Haberl EB, Brick J, Bass EB, Golden SH.

Ann Intern Med. 2012 Sep 4;157(5):336-47. Review.

PMID:
22777524
[PubMed - indexed for MEDLINE]
6.

Diabetes technology and treatments in the paediatric age group.

Shalitin S, Peter Chase H.

Int J Clin Pract Suppl. 2011 Feb;(170):76-82. doi: 10.1111/j.1742-1241.2010.02582.x. Review.

PMID:
21323816
[PubMed - indexed for MEDLINE]
7.

Continuous glucose monitoring for patients with diabetes: an evidence-based analysis.

Health Quality Ontario.

Ont Health Technol Assess Ser. 2011;11(4):1-29. Epub 2011 Jul 1.

PMID:
23074416
[PubMed]
Free PMC Article
8.

Blood glucose self-monitoring in type 2 diabetes: a randomised controlled trial.

Farmer AJ, Wade AN, French DP, Simon J, Yudkin P, Gray A, Craven A, Goyder L, Holman RR, Mant D, Kinmonth AL, Neil HA; DiGEM Trial Group.

Health Technol Assess. 2009 Feb;13(15):iii-iv, ix-xi, 1-50. doi: 10.3310/hta13150.

PMID:
19254484
[PubMed - indexed for MEDLINE]
Free Article
9.

Methods for Insulin Delivery and Glucose Monitoring: Comparative Effectiveness [Internet].

Golden SH, Brown T, Yeh HC, Maruthur N, Ranasinghe P, Berger Z, Suh Y, Wilson LM, Haberl EB, Bass EB.

Rockville (MD): Agency for Healthcare Research and Quality (US); 2012 Jul.

10.

Efficacy and safety comparison of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes: systematic review and meta-analysis.

Wojciechowski P, Ryś P, Lipowska A, Gawęska M, Małecki MT.

Pol Arch Med Wewn. 2011 Oct;121(10):333-43. Review.

PMID:
22045094
[PubMed - indexed for MEDLINE]
Free Article
11.

Methods for insulin delivery and glucose monitoring in diabetes: summary of a comparative effectiveness review.

Golden SH, Sapir T.

J Manag Care Pharm. 2012 Aug;18(6 Suppl):S1-17. Review.

PMID:
22984955
[PubMed - indexed for MEDLINE]
Free Article
12.

Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study.

Raccah D, Sulmont V, Reznik Y, Guerci B, Renard E, Hanaire H, Jeandidier N, Nicolino M.

Diabetes Care. 2009 Dec;32(12):2245-50. doi: 10.2337/dc09-0750. Epub 2009 Sep 18.

PMID:
19767384
[PubMed - indexed for MEDLINE]
Free PMC Article
13.

Self-monitoring of blood glucose in type 2 diabetes: systematic review.

Clar C, Barnard K, Cummins E, Royle P, Waugh N; Aberdeen Health Technology Assessment Group.

Health Technol Assess. 2010 Mar;14(12):1-140. doi: 10.3310/hta14120. Review.

PMID:
20226138
[PubMed - indexed for MEDLINE]
Free Article
15.

Mobile phone messaging for facilitating self-management of long-term illnesses.

de Jongh T, Gurol-Urganci I, Vodopivec-Jamsek V, Car J, Atun R.

Cochrane Database Syst Rev. 2012 Dec 12;12:CD007459. doi: 10.1002/14651858.CD007459.pub2. Review.

PMID:
23235644
[PubMed - indexed for MEDLINE]
16.

Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? A pilot study.

Petrovski G, Dimitrovski C, Bogoev M, Milenkovic T, Ahmeti I, Bitovska I.

Diabetes Technol Ther. 2011 Nov;13(11):1109-13. doi: 10.1089/dia.2011.0081. Epub 2011 Jul 13.

PMID:
21751889
[PubMed - indexed for MEDLINE]
17.

Beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials.

Szypowska A, Ramotowska A, Dzygalo K, Golicki D.

Eur J Endocrinol. 2012 Apr;166(4):567-74. doi: 10.1530/EJE-11-0642. Epub 2011 Nov 17. Review.

PMID:
22096111
[PubMed - indexed for MEDLINE]
Free Article
18.

Clinical effectiveness and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes: systematic review and economic evaluation.

Cummins E, Royle P, Snaith A, Greene A, Robertson L, McIntyre L, Waugh N.

Health Technol Assess. 2010 Feb;14(11):iii-iv, xi-xvi, 1-181. doi: 10.3310/hta14110. Review.

PMID:
20223123
[PubMed - indexed for MEDLINE]
Free Article
19.

Use of short-term real-time continuous glucose monitoring in type 1 diabetes patients on continuous intraperitoneal insulin infusion: a feasibility study.

Logtenberg SJ, Kleefstra N, Groenier KH, Gans RO, Bilo HJ.

Diabetes Technol Ther. 2009 May;11(5):293-9. doi: 10.1089/dia.2008.0088.

PMID:
19425877
[PubMed - indexed for MEDLINE]
20.

Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin.

Welschen LM, Bloemendal E, Nijpels G, Dekker JM, Heine RJ, Stalman WA, Bouter LM.

Cochrane Database Syst Rev. 2005 Apr 18;(2):CD005060. Review. Update in: Cochrane Database Syst Rev. 2012;1:CD005060.

PMID:
15846742
[PubMed - indexed for MEDLINE]

Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk