Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 156

1.

Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty.

Ezzet KA, Hermida JC, Steklov N, D'Lima DD.

J Arthroplasty. 2012 Jan;27(1):116-21. doi: 10.1016/j.arth.2011.06.002. Epub 2011 Sep 9.

PMID:
21908170
2.

Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator.

Ezzet KA, Hermida JC, Colwell CW Jr, D'Lima DD.

Clin Orthop Relat Res. 2004 Nov;(428):120-4.

PMID:
15534531
3.

Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.

Zietz C, Bergschmidt P, Lange R, Mittelmeier W, Bader R.

Int J Artif Organs. 2013 Jan;36(1):47-55. doi: 10.5301/ijao.5000189.

PMID:
23335379
4.

Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis.

Oonishi H, Ueno M, Kim SC, Oonishi H, Iwamoto M, Kyomoto M.

J Arthroplasty. 2009 Apr;24(3):374-82. doi: 10.1016/j.arth.2007.10.021. Epub 2008 Jun 4.

PMID:
18524533
5.

Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components.

White SE, Whiteside LA, McCarthy DS, Anthony M, Poggie RA.

Clin Orthop Relat Res. 1994 Dec;(309):176-84.

PMID:
7994957
6.

Increased force simulator wear testing of a zirconium oxide total knee arthroplasty.

Lee JK, Maruthainar K, Wardle N, Haddad F, Blunn GW.

Knee. 2009 Aug;16(4):269-74. doi: 10.1016/j.knee.2008.12.010. Epub 2009 Mar 25.

PMID:
19321347
7.

Polyethylene wear and variations in knee kinematics.

D'Lima DD, Hermida JC, Chen PC, Colwell CW Jr.

Clin Orthop Relat Res. 2001 Nov;(392):124-30.

PMID:
11716373
8.

Retrieval analysis of femoral zirconium components in total knee arthroplasty: preliminary results.

Heyse TJ, Davis J, Haas SB, Chen DX, Wright TM, Laskin RS.

J Arthroplasty. 2011 Apr;26(3):445-50. doi: 10.1016/j.arth.2009.11.024. Epub 2010 Feb 9.

PMID:
20149583
9.

No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

Minoda Y, Hata K, Iwaki H, Ikebuchi M, Hashimoto Y, Inori F, Nakamura H.

Knee Surg Sports Traumatol Arthrosc. 2014 Mar;22(3):680-6. doi: 10.1007/s00167-013-2724-4. Epub 2013 Oct 20.

PMID:
24141905
10.

Matched-pair total knee arthroplasty retrieval analysis: oxidized zirconium vs. CoCrMo.

Heyse TJ, Chen DX, Kelly N, Boettner F, Wright TM, Haas SB.

Knee. 2011 Dec;18(6):448-52. doi: 10.1016/j.knee.2010.08.011. Epub 2010 Sep 24.

PMID:
20869251
11.

Effect of tibial component varus on wear in total knee arthroplasty.

Srivastava A, Lee GY, Steklov N, Colwell CW Jr, Ezzet KA, D'Lima DD.

Knee. 2012 Oct;19(5):560-3. doi: 10.1016/j.knee.2011.11.003. Epub 2011 Dec 27.

PMID:
22206820
12.

Knee simulator wear of polyethylene tibias articulating against explanted rough femoral components.

Muratoglu OK, Burroughs BR, Bragdon CR, Christensen S, Lozynsky A, Harris WH.

Clin Orthop Relat Res. 2004 Nov;(428):108-13.

PMID:
15534529
13.

Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation.

Tsukamoto R, Chen S, Asano T, Ogino M, Shoji H, Nakamura T, Clarke IC.

Acta Orthop. 2006 Jun;77(3):505-11.

PMID:
16819693
14.

[Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

Vavrík P, Landor I, Denk F.

Acta Chir Orthop Traumatol Cech. 2008 Dec;75(6):436-42. Czech.

PMID:
19150000
15.
16.

The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis.

Liau JJ, Cheng CK, Huang CH, Lo WH.

Clin Biomech (Bristol, Avon). 2002 Feb;17(2):140-6.

PMID:
11832264
17.

Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert.

Muratoglu OK, Rubash HE, Bragdon CR, Burroughs BR, Huang A, Harris WH.

J Arthroplasty. 2007 Apr;22(3):435-44. Erratum in: J Arthroplasty. 2008 Jan;23(1):158.

PMID:
17400100
18.

Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.

Kim YH, Kim JS, Huh W, Lee KH.

Clin Orthop Relat Res. 2010 May;468(5):1296-304. doi: 10.1007/s11999-009-1179-x. Epub 2009 Dec 1.

19.

Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.

Benson LC, DesJardins JD, LaBerge M.

J Biomed Mater Res. 2001;58(5):496-504.

PMID:
11505423
20.

Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium.

Brandt JM, Guenther L, O'Brien S, Vecherya A, Turgeon TR, Bohm ER.

Knee. 2013 Dec;20(6):388-96. doi: 10.1016/j.knee.2013.01.004. Epub 2013 Apr 11.

PMID:
23583666
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk