Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 163

1.

A novel oscillometric device for peripheral arterial disease screening in everyday practice. The Czech-post MONICA study.

Wohlfahrt P, Ingrischová M, Krajcoviechová A, Palous D, Dolejsová M, Seidlerová J, Galovcová M, Bruthans J, Jozífová M, Adámková V, Filipovský J, Cífková R.

Int Angiol. 2011 Jun;30(3):256-61.

PMID:
21617609
2.

Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease.

Sinski M, Styczynski G, Szmigielski C.

Hypertens Res. 2013 Jan;36(1):25-8. doi: 10.1038/hr.2012.120. Epub 2012 Aug 9.

PMID:
22875071
3.

Accuracy of the ankle-brachial index using the SCVL(®), an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk.

Rosenbaum D, Rodriguez-Carranza S, Laroche P, Bruckert E, Giral P, Girerd X.

Vasc Health Risk Manag. 2012;8:239-46. doi: 10.2147/VHRM.S29405. Epub 2012 Apr 17.

4.

Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor profile.

Kollias A, Xilomenos A, Protogerou A, Dimakakos E, Stergiou GS.

Hypertens Res. 2011 Jul;34(7):825-30. doi: 10.1038/hr.2011.53. Epub 2011 May 19.

PMID:
21593742
5.

[Peripheral arterial disease: efficacy of the oscillometric method].

Vega J, Romaní S, Garcipérez FJ, Vicente L, Pacheco N, Zamorano J, Gómez-Barrado JJ, Sánchez Muñoz-Torrero JF.

Rev Esp Cardiol. 2011 Jul;64(7):619-21. doi: 10.1016/j.recesp.2010.10.019. Epub 2011 Mar 23. Spanish.

6.

Automated oscillometric determination of the ankle-brachial index: a systematic review and meta-analysis.

Verberk WJ, Kollias A, Stergiou GS.

Hypertens Res. 2012 Sep;35(9):883-91. doi: 10.1038/hr.2012.83. Epub 2012 Jun 28. Review.

PMID:
22739420
7.

Preliminary assessment of an automatic screening device for peripheral arterial disease using ankle-brachial and toe-brachial indices.

Harrison ML, Lin HF, Blakely DW, Tanaka H.

Blood Press Monit. 2011 Jun;16(3):138-41. doi: 10.1097/MBP.0b013e328346a839.

PMID:
21494126
8.

The ankle--brachial index and the diabetic foot: a troublesome marriage.

Aerden D, Massaad D, von Kemp K, van Tussenbroek F, Debing E, Keymeulen B, Van den Brande P.

Ann Vasc Surg. 2011 Aug;25(6):770-7. doi: 10.1016/j.avsg.2010.12.025. Epub 2011 Apr 21.

PMID:
21514102
9.

Automated ankle-brachial pressure index measurement by clinical staff for peripheral arterial disease diagnosis in nondiabetic and diabetic patients.

Clairotte C, Retout S, Potier L, Roussel R, Escoubet B.

Diabetes Care. 2009 Jul;32(7):1231-6. doi: 10.2337/dc08-2230. Epub 2009 Apr 14.

10.

Validation study of automated oscillometric measurement of the ankle-brachial index for lower arterial occlusive disease by comparison with computed tomography angiography.

Ichihashi S, Hashimoto T, Iwakoshi S, Kichikawa K.

Hypertens Res. 2014 Jun;37(6):591-4. doi: 10.1038/hr.2014.34. Epub 2014 Mar 6.

PMID:
24599013
12.

Measurement of blood pressure, ankle blood pressure and calculation of ankle brachial index in general practice.

Nexøe J, Damsbo B, Lund JO, Munck A.

Fam Pract. 2012 Jun;29(3):345-51. doi: 10.1093/fampra/cmr094. Epub 2011 Oct 23.

13.

Comparison between oscillometric- and Doppler-ABI in elderly individuals.

Takahashi I, Furukawa K, Ohishi W, Takahashi T, Matsumoto M, Fujiwara S.

Vasc Health Risk Manag. 2013;9:89-94. doi: 10.2147/VHRM.S39785. Epub 2013 Mar 8.

14.

Ankle brachial index and pneumoplethysmographic pulse-volume recordings for detection of peripheral arterial disease.

Jahn J, Zimmermann W, Moysidis T, Kröger K.

Vasa. 2014 May;43(3):202-8. doi: 10.1024/0301-1526/a000350.

PMID:
24797052
15.

Detection of atherosclerosis by ankle brachial index: evaluation of palpatory method versus ultrasound Doppler technique.

Akhtar B, Siddique S, Khan RA, Zulfiqar S.

J Ayub Med Coll Abbottabad. 2009 Jan-Mar;21(1):11-6.

PMID:
20364731
16.

Automated photoplethysmography-based determination of ankle-brachial index: a validation study against Doppler sonography.

Beutner F, Teren A, Gielen S, Schuler G, Wirkner K, Tiller D, Loeffler M, Scholz M.

Clin Res Cardiol. 2012 Nov;101(11):875-83. doi: 10.1007/s00392-012-0471-z. Epub 2012 May 15.

PMID:
22584382
17.

Comparison of ankle-brachial index measured by an automated oscillometric apparatus with that by standard Doppler technique in vascular patients.

Kornø M, Eldrup N, Sillesen H.

Eur J Vasc Endovasc Surg. 2009 Nov;38(5):610-5. doi: 10.1016/j.ejvs.2009.07.004. Epub 2009 Sep 13.

18.
19.

A high ankle-brachial index is associated with increased aortic pulse wave velocity: the Czech post-MONICA study.

Wohlfahrt P, Palous D, Ingrischová M, Krajcoviechová A, Seidlerová J, Galovcová M, Bruthans J, Jozífová M, Adámková V, Filipovsky J, Cífková R.

Eur J Cardiovasc Prev Rehabil. 2011 Dec;18(6):790-6. doi: 10.1177/1741826711398840. Epub 2011 Mar 1.

PMID:
21450589
20.

Automated oscillometric determination of the ankle-brachial index provides accuracy necessary for office practice.

Beckman JA, Higgins CO, Gerhard-Herman M.

Hypertension. 2006 Jan;47(1):35-8. Epub 2005 Dec 12.

Items per page

Supplemental Content

Write to the Help Desk