Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 543

1.

[Preoperative staging of axillary lymph nodes in breast cancer: ultrasonographic parameters and ultrasound-guided core needle biopsy].

Torres Sousa MY, Banegas Illescas ME, Rozas Rodríguez ML, Arias Ortega M, González López LM, Martín García JJ, Ruiz Ortega L.

Radiologia. 2011 Nov-Dec;53(6):544-51. doi: 10.1016/j.rx.2010.12.007. Epub 2011 May 11. Spanish.

2.

Role of axillary lymph node ultrasound and large core biopsy in the preoperative assessment of patients selected for sentinel node biopsy.

Nori J, Bazzocchi M, Boeri C, Vanzi E, Nori Bufalini F, Mangialavori G, Distante V, Masi A, Simoncini R, Londero V.

Radiol Med. 2005 Apr;109(4):330-44. English, Italian.

PMID:
15883518
3.

Axillary lymph nodes suspicious for breast cancer metastasis: sampling with US-guided 14-gauge core-needle biopsy--clinical experience in 100 patients.

Abe H, Schmidt RA, Kulkarni K, Sennett CA, Mueller JS, Newstead GM.

Radiology. 2009 Jan;250(1):41-9. doi: 10.1148/radiol.2493071483. Epub 2008 Oct 27.

PMID:
18955508
4.

[Role of ultrasound-guided needle biopsy of ultrasonographic abnormal axillary lymph nodes in patients with breast cancer].

Ou YT, Li JF, Fan ZQ, Fan T, Wang TF, Xie YT, Lin BY.

Zhonghua Yi Xue Za Zhi. 2008 Jan 8;88(2):82-4. Chinese.

PMID:
18353208
5.

Pretreatment axillary ultrasonography and core biopsy in patients with suspected breast cancer: diagnostic accuracy and impact on management.

Garcia-Ortega MJ, Benito MA, Vahamonde EF, Torres PR, Velasco AB, Paredes MM.

Eur J Radiol. 2011 Jul;79(1):64-72. doi: 10.1016/j.ejrad.2009.12.011. Epub 2010 Jan 4.

PMID:
20047809
6.

Ultrasonography and fine-needle aspiration cytology can spare breast cancer patients unnecessary sentinel lymph node biopsy.

van Rijk MC, Deurloo EE, Nieweg OE, Gilhuijs KG, Peterse JL, Rutgers EJ, Kröger R, Kroon BB.

Ann Surg Oncol. 2006 Jan;13(1):31-5. Epub 2006 Jan 1.

PMID:
16372147
7.

Ultrasound and fine needle aspiration cytology of axillary lymph nodes in breast cancer. To do or not to do?

Leenders MW, Broeders M, Croese C, Richir MC, Go HL, Langenhorst BL, Meijer S, Schreurs WH.

Breast. 2012 Aug;21(4):578-83. doi: 10.1016/j.breast.2012.05.008. Epub 2012 Jun 19.

PMID:
22717665
8.

Preoperative sonographic classification of axillary lymph nodes in patients with breast cancer: node-to-node correlation with surgical histology and sentinel node biopsy results.

Cho N, Moon WK, Han W, Park IA, Cho J, Noh DY.

AJR Am J Roentgenol. 2009 Dec;193(6):1731-7. doi: 10.2214/AJR.09.3122.

PMID:
19933672
9.

Comparison of sonography with sonographically guided fine-needle aspiration biopsy and core-needle biopsy for initial axillary staging of breast cancer.

Ahn HS, Kim SM, Jang M, La Yun B, Kim SW, Kang E, Park SY, Moon WK, Choi HY.

J Ultrasound Med. 2013 Dec;32(12):2177-84. doi: 10.7863/ultra.32.12.2177.

10.

Role of ultrasound-guided core needle biopsy of axillary lymph nodes in the initial staging of breast carcinoma.

Topal U, Punar S, Taşdelen I, Adim SB.

Eur J Radiol. 2005 Dec;56(3):382-5. Epub 2005 Jul 15.

PMID:
16024205
11.

Preoperative axillary staging in breast cancer-saving time and resources.

Tahir M, Osman KA, Shabbir J, Rogers C, Suarez R, Reynolds T, Bucknall T.

Breast J. 2008 Jul-Aug;14(4):369-71. doi: 10.1111/j.1524-4741.2008.00600.x.

PMID:
18540958
12.

Use of ultrasound-guided axillary node core biopsy in staging of early breast cancer.

Britton PD, Goud A, Godward S, Barter S, Freeman A, Gaskarth M, Rajan P, Sinnatamby R, Slattery J, Provenzano E, O'Donovan M, Pinder S, Benson JR, Forouhi P, Wishart GC.

Eur Radiol. 2009 Mar;19(3):561-9. doi: 10.1007/s00330-008-1177-5. Epub 2008 Sep 17.

PMID:
18797874
13.

Nonimage-guided fine needle aspiration biopsy of palpable axillary lymph nodes in breast cancer patients.

Marti JL, Ayo D, Levine P, Hernandez O, Rescigno J, Axelrod DM.

Breast J. 2012 Jan-Feb;18(1):3-7. doi: 10.1111/j.1524-4741.2011.01180.x. Epub 2011 Nov 20.

PMID:
22098412
14.

Preoperative ultrasound-guided fine-needle aspiration cytology for axillary staging in breast carcinoma.

Popli MB, Sahoo M, Mehrotra N, Choudhury M, Kumar A, Pathania OP, Thomas S.

Australas Radiol. 2006 Apr;50(2):122-6. Erratum in: Australas Radiol. 2006 Oct;50(5):512.

PMID:
16635029
15.

Cost/accuracy ratio analysis in breast cancer patients undergoing ultrasound-guided fine-needle aspiration cytology, sentinel node biopsy, and frozen section of node.

Genta F, Zanon E, Camanni M, Deltetto F, Drogo M, Gallo R, Gilardi C.

World J Surg. 2007 Jun;31(6):1155-63.

PMID:
17464539
16.

Axillary ultrasound and fine-needle aspiration in the preoperative evaluation of the breast cancer patient: an algorithm based on tumor size and lymph node appearance.

Mainiero MB, Cinelli CM, Koelliker SL, Graves TA, Chung MA.

AJR Am J Roentgenol. 2010 Nov;195(5):1261-7. doi: 10.2214/AJR.10.4414.

PMID:
20966338
17.

Multicentre study of ultrasonographically guided axillary node biopsy in patients with breast cancer.

de Kanter AY, van Eijck CH, van Geel AN, Kruijt RH, Henzen SC, Paul MA, Eggermont AM, Wiggers T.

Br J Surg. 1999 Nov;86(11):1459-62.

PMID:
10583296
18.

Is the clinically positive axilla in breast cancer really a contraindication to sentinel lymph node biopsy?

Specht MC, Fey JV, Borgen PI, Cody HS 3rd.

J Am Coll Surg. 2005 Jan;200(1):10-4.

PMID:
15631914
19.

Conservation of the axilla: an audit of sentinel lymph node biopsy after a new start.

Apostolopoulos A, Basit A, Kirby RM, Adjogatse JK, Lambert G, Chan KY, Hancock A, Hackney L, Wall M.

Clin Breast Cancer. 2011 Aug;11(4):264-7. doi: 10.1016/j.clbc.2011.04.007. Epub 2011 Jun 12.

PMID:
21715231
20.

Influence of tumor histology on preoperative staging accuracy of breast metastases to the axilla.

Hackney L, Williams S, Bajwa S, Morley-Davies AJ, Kirby RM, Britton I.

Breast J. 2013 Jan-Feb;19(1):49-55. doi: 10.1111/tbj.12042. Epub 2012 Nov 27.

PMID:
23186153
Items per page

Supplemental Content

Write to the Help Desk