Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 105

1.

A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation.

Gu X, Jelen U, Li J, Jia X, Jiang SB.

Phys Med Biol. 2011 Jun 7;56(11):3337-50. doi: 10.1088/0031-9155/56/11/010. Epub 2011 May 10.

2.

Adaptive beamlet-based finite-size pencil beam dose calculation for independent verification of IMRT and VMAT.

Park JC, Li JG, Arhjoul L, Yan G, Lu B, Fan Q, Liu C.

Med Phys. 2015 Apr;42(4):1836-50. doi: 10.1118/1.4914858.

PMID:
25832074
3.

[CUDA-based fast dose calculation in radiotherapy].

Wang X, Liu C, Hou Q.

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011 Oct;28(5):881-5. Chinese.

PMID:
22097248
4.

GPU-based ultra-fast dose calculation using a finite size pencil beam model.

Gu X, Choi D, Men C, Pan H, Majumdar A, Jiang SB.

Phys Med Biol. 2009 Oct 21;54(20):6287-97. doi: 10.1088/0031-9155/54/20/017. Epub 2009 Oct 1.

PMID:
19794244
5.

Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine.

Zhu J, Chen L, Chen A, Luo G, Deng X, Liu X.

Radiat Oncol. 2015 Apr 11;10:85. doi: 10.1186/s13014-015-0387-7.

6.

A finite size pencil beam algorithm for IMRT dose optimization: density corrections.

Jeleń U, Alber M.

Phys Med Biol. 2007 Feb 7;52(3):617-33. Epub 2007 Jan 10.

PMID:
17228109
7.

Monte Carlo vs. pencil beam based optimization of stereotactic lung IMRT.

Sikora M, Muzik J, Söhn M, Weinmann M, Alber M.

Radiat Oncol. 2009 Dec 12;4:64. doi: 10.1186/1748-717X-4-64.

8.

Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck.

Wang L, Yorke E, Chui CS.

Int J Radiat Oncol Biol Phys. 2001 Aug 1;50(5):1339-49.

PMID:
11483347
9.

A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures.

Neylon J, Sheng K, Yu V, Chen Q, Low DA, Kupelian P, Santhanam A.

Med Phys. 2014 Oct;41(10):101711. doi: 10.1118/1.4895822.

PMID:
25281950
10.

Algorithm and performance of a clinical IMRT beam-angle optimization system.

Djajaputra D, Wu Q, Wu Y, Mohan R.

Phys Med Biol. 2003 Oct 7;48(19):3191-212.

PMID:
14579860
11.

GPU-based fast pencil beam algorithm for proton therapy.

Fujimoto R, Kurihara T, Nagamine Y.

Phys Med Biol. 2011 Mar 7;56(5):1319-28. doi: 10.1088/0031-9155/56/5/006. Epub 2011 Feb 4.

PMID:
21297243
12.

Monte Carlo dose computation for IMRT optimization.

Laub W, Alber M, Birkner M, Nüsslin F.

Phys Med Biol. 2000 Jul;45(7):1741-54.

PMID:
10943916
13.

Evaluation of a pencil-beam dose calculation technique for charged particle radiotherapy.

Petti PL.

Int J Radiat Oncol Biol Phys. 1996 Jul 15;35(5):1049-57.

PMID:
8751415
14.

GPU-based Monte Carlo radiotherapy dose calculation using phase-space sources.

Townson RW, Jia X, Tian Z, Graves YJ, Zavgorodni S, Jiang SB.

Phys Med Biol. 2013 Jun 21;58(12):4341-56. doi: 10.1088/0031-9155/58/12/4341. Epub 2013 Jun 4.

PMID:
23732697
15.

IMRT head and neck treatment planning with a commercially available Monte Carlo based planning system.

Boudreau C, Heath E, Seuntjens J, Ballivy O, Parker W.

Phys Med Biol. 2005 Mar 7;50(5):879-90. Epub 2005 Feb 17.

PMID:
15798262
16.

GPU-based fast Monte Carlo simulation for radiotherapy dose calculation.

Jia X, Gu X, Graves YJ, Folkerts M, Jiang SB.

Phys Med Biol. 2011 Nov 21;56(22):7017-31. doi: 10.1088/0031-9155/56/22/002. Epub 2011 Oct 21.

PMID:
22016026
17.

Clinical implementation of a GPU-based simplified Monte Carlo method for a treatment planning system of proton beam therapy.

Kohno R, Hotta K, Nishioka S, Matsubara K, Tansho R, Suzuki T.

Phys Med Biol. 2011 Nov 21;56(22):N287-94. doi: 10.1088/0031-9155/56/22/N03. Epub 2011 Oct 28.

PMID:
22036894
18.

Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine.

Seco J, Adams E, Bidmead M, Partridge M, Verhaegen F.

Phys Med Biol. 2005 Mar 7;50(5):817-30. Epub 2005 Feb 17.

PMID:
15798257
19.

Efficient implementation of the 3D-DDA ray traversal algorithm on GPU and its application in radiation dose calculation.

Xiao K, Chen DZ, Hu XS, Zhou B.

Med Phys. 2012 Dec;39(12):7619-25. doi: 10.1118/1.4767755.

PMID:
23231309
20.

In aqua vivo EPID dosimetry.

Wendling M, McDermott LN, Mans A, Olaciregui-Ruiz Í, Pecharromán-Gallego R, Sonke JJ, Stroom J, van Herk M, Mijnheer BJ.

Med Phys. 2012 Jan;39(1):367-77. doi: 10.1118/1.3665709.

PMID:
22225306
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk