Items: 1 to 20 of 250


Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm?

Moroni A, Savarino L, Hoque M, Cadossi M, Baldini N.

Clin Orthop Relat Res. 2011 Jan;469(1):180-7. doi: 10.1007/s11999-010-1424-3. Epub 2010 Jun 11.


Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

Savarino L, Cadossi M, Chiarello E, Baldini N, Giannini S.

Clin Orthop Relat Res. 2013 Sep;471(9):2964-71. doi: 10.1007/s11999-013-2981-z. Epub 2013 Apr 10.


Does ion release differ between hip resurfacing and metal-on-metal THA?

Moroni A, Savarino L, Cadossi M, Baldini N, Giannini S.

Clin Orthop Relat Res. 2008 Mar;466(3):700-7. doi: 10.1007/s11999-007-0106-2. Epub 2008 Jan 9.


Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.

Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP.

Acta Orthop. 2006 Oct;77(5):697-705.


Do survival rate and serum ion concentrations 10 years after metal-on-metal hip resurfacing provide evidence for continued use?

Hartmann A, Lützner J, Kirschner S, Witzleb WC, Günther KP.

Clin Orthop Relat Res. 2012 Nov;470(11):3118-26. doi: 10.1007/s11999-012-2329-0.


What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Bayley N, Khan H, Grosso P, Hupel T, Stevens D, Snider M, Schemitsch E, Kuzyk P.

Clin Orthop Relat Res. 2015 Feb;473(2):477-84. doi: 10.1007/s11999-014-3824-2.


Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Hart AJ, Skinner JA, Henckel J, Sampson B, Gordon F.

Clin Orthop Relat Res. 2011 Sep;469(9):2590-7. doi: 10.1007/s11999-011-1930-y. Epub 2011 Jun 9.


The effect of obesity on blood metal ion levels after hip resurfacing and metal-on-metal total hip replacement.

Sawalha S, Ravikumar R, Chowdhury EA, Massraf A.

Hip Int. 2012 Jan-Feb;22(1):107-12. doi: 10.5301/HIP.2012.9034.


Do the potential benefits of metal-on-metal hip resurfacing justify the increased cost and risk of complications?

Bozic KJ, Pui CM, Ludeman MJ, Vail TP, Silverstein MD.

Clin Orthop Relat Res. 2010 Sep;468(9):2301-12. doi: 10.1007/s11999-010-1301-0.


The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing.

Bartelt RB, Yuan BJ, Trousdale RT, Sierra RJ.

Clin Orthop Relat Res. 2010 Sep;468(9):2346-56. doi: 10.1007/s11999-010-1356-y.


Metal ion levels in total hip arthroplasty versus hip resurfacing.

Johnson AJ, Le Duff MJ, Yoon JP, Al-Hamad M, Amstutz HC.

J Arthroplasty. 2013 Aug;28(7):1235-7. doi: 10.1016/j.arth.2013.03.015. Epub 2013 Apr 22.


Metal ion interpretation in resurfacing versus conventional hip arthroplasty and in whole blood versus serum. How should we interpret metal ion data.

Smolders JM, Bisseling P, Hol A, Van Der Straeten C, Schreurs BW, van Susante JL.

Hip Int. 2011 Sep-Oct;21(5):587-95. doi: 10.5301/HIP.2011.8643.


Serum metal ion concentrations after unilateral vs bilateral large-head metal-on-metal primary total hip arthroplasty.

Pelt CE, Bergeson AG, Anderson LA, Stoddard GJ, Peters CL.

J Arthroplasty. 2011 Dec;26(8):1494-500. doi: 10.1016/j.arth.2011.03.037. Epub 2011 May 13.


Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty.

Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J.

Int Orthop. 2012 Sep;36(9):1807-12. doi: 10.1007/s00264-012-1570-1. Epub 2012 Jun 9.


The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP.

Clin Orthop Relat Res. 2010 Feb;468(2):318-25. doi: 10.1007/s11999-009-1029-x. Epub 2009 Aug 21.


Metal-on-metal total hip arthroplasty - five- to 11-year follow-up.

Nikolaou VS, Petit A, Debiparshad K, Huk OL, Zukor DJ, Antoniou J.

Bull NYU Hosp Jt Dis. 2011;69 Suppl 1:S77-83.


Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty--preliminary results of a prospective five year study after two years of follow-up.

Maurer-Ertl W, Friesenbichler J, Sadoghi P, Pechmann M, Trennheuser M, Leithner A.

BMC Musculoskelet Disord. 2012 Apr 11;13:56. doi: 10.1186/1471-2474-13-56.


The withdrawn ASR™ THA and hip resurfacing systems: how have our patients fared over 1 to 6 years?

Hug KT, Watters TS, Vail TP, Bolognesi MP.

Clin Orthop Relat Res. 2013 Feb;471(2):430-8. doi: 10.1007/s11999-012-2547-5.


The effect of operative factors on outlier ion levels in patients with metal-on-metal hip arthroplasties.

Bernstein M, Gupta S, Petit A, Zukor DJ, Huk OL, Antoniou J.

Bull NYU Hosp Jt Dis. 2011;69 Suppl 1:S20-6.


Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.

Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL.

J Bone Joint Surg Am. 2008 Aug;90 Suppl 3:142-8. doi: 10.2106/JBJS.H.00442.