Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 112

Similar articles for PubMed (Select 20527545)

1.

Adaptive spatial calibration of a 3D ultrasound system.

Hartov A, Paulsen K, Ji S, Fontaine K, Furon ML, Borsic A, Roberts D.

Med Phys. 2010 May;37(5):2121-30.

2.

Bore-Sight Calibration of Multiple Laser Range Finders for Kinematic 3D Laser Scanning Systems.

Jung J, Kim J, Yoon S, Kim S, Cho H, Kim C, Heo J.

Sensors (Basel). 2015 May 4;15(5):10292-314. doi: 10.3390/s150510292.

3.

Versatile robotic probe calibration for position tracking in ultrasound imaging.

Bø LE, Hofstad EF, Lindseth F, Hernes TA.

Phys Med Biol. 2015 May 7;60(9):3499-513. doi: 10.1088/0031-9155/60/9/3499. Epub 2015 Apr 9.

PMID:
25855886
4.

A closed-form differential formulation for ultrasound spatial calibration: single wall phantom.

Najafi M, Afsham N, Abolmaesumi P, Rohling R.

Ultrasound Med Biol. 2015 Apr;41(4):1079-94. doi: 10.1016/j.ultrasmedbio.2014.11.020. Epub 2015 Feb 18.

PMID:
25701520
5.

Calibration of a 3D endoscopic system based on active stereo method for shape measurement of biological tissues and specimen.

Furukawa R, Aoyama M, Hiura S, Aoki H, Kominami Y, Sanomura Y, Yoshida S, Tanaka S, Sagawa R, Kawasaki H.

Conf Proc IEEE Eng Med Biol Soc. 2014 Aug;2014:4991-4. doi: 10.1109/EMBC.2014.6944745.

PMID:
25571113
6.

Voltage compensation based calibration measurement of 3D-acceleration transducer in fall detection system for the elderly.

Zheng L, Wang L, He D, Geng N, Geng P, Guan D, Xu L.

Conf Proc IEEE Eng Med Biol Soc. 2014;2014:2773-6. doi: 10.1109/EMBC.2014.6944198.

PMID:
25570566
7.

Boresight calibration of construction misalignments for 3D scanners built with a 2D laser range finder rotating on its optical center.

Morales J, Martínez JL, Mandow A, Reina AJ, Pequeño-Boter A, García-Cerezo A.

Sensors (Basel). 2014 Oct 24;14(11):20025-40. doi: 10.3390/s141120025.

8.

Global calibration and equation reconstruction methods of a three dimensional curve generated from a laser plane in vision measurement.

Xu G, Sun L, Li X, Su J, Hao Z, Lu X.

Opt Express. 2014 Sep 8;22(18):22043-55. doi: 10.1364/OE.22.022043.

PMID:
25321578
9.

A flexile and high precision calibration method for binocular structured light scanning system.

Yuan J, Wang Q, Li B.

ScientificWorldJournal. 2014;2014:753932. doi: 10.1155/2014/753932. Epub 2014 Aug 18.

10.

Optimization for calibration of large-scale optical measurement positioning system by using spherical constraint.

Zhao Z, Zhu J, Xue B, Yang L.

J Opt Soc Am A Opt Image Sci Vis. 2014 Jul 1;31(7):1427-35. doi: 10.1364/JOSAA.31.001427.

PMID:
25121428
11.

Indoor magnetic signature based localization algorithm without person-dependent parameter calibration.

Suh YS, Amarbayasgalan B.

Sensors (Basel). 2014 Aug 7;14(8):14375-98. doi: 10.3390/s140814375.

12.

Novel calibration algorithm for a three-axis strapdown magnetometer.

Liu YX, Li XS, Zhang XJ, Feng YB.

Sensors (Basel). 2014 May 14;14(5):8485-504. doi: 10.3390/s140508485.

13.

Precise calibration of binocular vision system used for vision measurement.

Cui Y, Zhou F, Wang Y, Liu L, Gao H.

Opt Express. 2014 Apr 21;22(8):9134-49. doi: 10.1364/OE.22.009134.

PMID:
24787804
14.

Interactive initialization of 2D/3D rigid registration.

Gong RH, Güler Ö, Kürklüoglu M, Lovejoy J, Yaniv Z.

Med Phys. 2013 Dec;40(12):121911. doi: 10.1118/1.4830428.

PMID:
24320522
15.

A 3D ultrasound scanning system for image guided liver interventions.

Neshat H, Cool DW, Barker K, Gardi L, Kakani N, Fenster A.

Med Phys. 2013 Nov;40(11):112903. doi: 10.1118/1.4824326.

PMID:
24320470
16.

Automatic 3D ultrasound calibration for image guided therapy using intramodality image registration.

Schlosser J, Kirmizibayrak C, Shamdasani V, Metz S, Hristov D.

Phys Med Biol. 2013 Nov 7;58(21):7481-96. doi: 10.1088/0031-9155/58/21/7481. Epub 2013 Oct 8.

17.

A visual servoing-based method for ProCam systems calibration.

Berry F, Aider OA, Mosnier J.

Sensors (Basel). 2013 Oct 1;13(10):13318-33. doi: 10.3390/s131013318.

18.

Automatic needle detection and tracking in 3D ultrasound using an ROI-based RANSAC and Kalman method.

Zhao Y, Cachard C, Liebgott H.

Ultrason Imaging. 2013 Oct;35(4):283-306. doi: 10.1177/0161734613502004.

PMID:
24081726
19.

Improving N-wire phantom-based freehand ultrasound calibration.

Carbajal G, Lasso A, Gómez A, Fichtinger G.

Int J Comput Assist Radiol Surg. 2013 Nov;8(6):1063-72. doi: 10.1007/s11548-013-0904-9. Epub 2013 Jul 28.

PMID:
23892996
20.

Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.

Sridharan A, Eisenbrey JR, Liu JB, Machado P, Halldorsdottir VG, Dave JK, Zhao H, He Y, Park S, Dianis S, Wallace K, Thomenius KE, Forsberg F.

Invest Radiol. 2013 Sep;48(9):654-60. doi: 10.1097/RLI.0b013e3182925160.

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk