Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 156

Similar articles for PubMed (Select 15978461)

1.

Liver resection using a saline-linked radiofrequency dissecting sealer for transection of the liver.

Tan HP, Marsh W, Marcos A.

J Am Coll Surg. 2005 Jul;201(1):152; author reply 153-4. No abstract available.

PMID:
15978461
2.

Effectiveness of using ultrasonically activated scalpel in combination with radiofrequency dissecting sealer or irrigation bipolar for hepatic resection.

Yokoo H, Kamiyama T, Nakanishi K, Tahara M, Fukumori D, Kamachi H, Matsushita M, Todo S.

Hepatogastroenterology. 2012 May;59(115):831-5. doi: 10.5754/hge10337.

PMID:
22469727
3.

Liver resection using a saline-linked radiofrequency dissecting sealer for transection of the liver.

Poon RT, Fan ST, Wong J.

J Am Coll Surg. 2005 Feb;200(2):308-13. No abstract available.

PMID:
15664110
4.

In-line radiofrequency ablation to minimize blood loss in hepatic parenchymal transection.

Haghighi KS, Wang F, King J, Daniel S, Morris DL.

Am J Surg. 2005 Jul;190(1):43-7.

PMID:
15972170
5.

Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver.

Navarro A, Burdio F, Berjano EJ, Güemes A, Sousa R, Rufas M, Subirá J, Gonzalez A, Burdío JM, Castiella T, Tejero E, De Gregorio MA, Grande L, Lozano R.

Surg Endosc. 2008 May;22(5):1384-91. doi: 10.1007/s00464-008-9793-3. Epub 2008 Mar 6.

PMID:
18322742
6.

Randomized clinical trial of the effect of a saline-linked radiofrequency coagulator on blood loss during hepatic resection.

Arita J, Hasegawa K, Kokudo N, Sano K, Sugawara Y, Makuuchi M.

Br J Surg. 2005 Aug;92(8):954-9.

PMID:
16034832
7.

The use of saline-linked radiofrequency dissecting sealer for liver transection in patients with cirrhosis.

Xia F, Wang S, Ma K, Feng X, Su Y, Dong J.

J Surg Res. 2008 Sep;149(1):110-4. doi: 10.1016/j.jss.2008.01.002. Epub 2008 Feb 1.

PMID:
18541264
8.

[Radiofrequency assisted liver resection in non-cirhotic liver. Initial clinical experience].

Ferko A, Lesko M, Subrt Z, Hoffmann P, Melichar B, Dvorák P, Vacek Z, Motycka P, Kocí J.

Rozhl Chir. 2006 Jun;85(6):280-4; discussion 284-5. Czech.

PMID:
16977865
9.

New technique for liver resection using heat coagulative necrosis.

Machi J.

Ann Surg. 2005 Jan;241(1):194-6. No abstract available.

10.

Experience with TissueLink--radiofrequency-assisted parenchymal division.

Hutchins R, Bertucci M.

Dig Surg. 2007;24(4):318-21. Epub 2007 Jul 27.

PMID:
17657159
11.

[Radio-frequency ablation appliance in resection of the liver].

Fedorov VD, Vishnevskiĭ VA, Kubyshkin VA, Korniak BS, Ikramov RZ, Gavrilin AV, Shchegolev AI, Sergeeva ON, Ionkin DA, Tarasiuk TI.

Khirurgiia (Mosk). 2004;(5):21-5. Russian.

PMID:
15159755
12.

Impact of radiofrequency assisted hepatectomy for reduction of transfusion requirements.

Ayav A, Bachellier P, Habib NA, Pellicci R, Tierris J, Milicevic M, Jiao LR.

Am J Surg. 2007 Feb;193(2):143-8.

PMID:
17236838
13.

[Use of linear radiofrequency device in liver resection].

Stojanović M, Radojković M, Stanojević G.

Vojnosanit Pregl. 2010 Nov;67(11):910-5. Serbian.

PMID:
21268926
14.

A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study.

Burdío F, Grande L, Berjano E, Martinez-Serrano M, Poves I, Burdío JM, Navarro A, Güemes A.

Am J Surg. 2010 Dec;200(6):e75-80. doi: 10.1016/j.amjsurg.2010.02.020.

PMID:
20864082
15.

Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection.

Lupo L, Gallerani A, Panzera P, Tandoi F, Di Palma G, Memeo V.

Br J Surg. 2007 Mar;94(3):287-91.

PMID:
17318804
16.

Radiofrequency assisted liver resection--a novel technique.

Jiao LR, Navarra G, Weber JC, Havlik R, Nicholls JP, Habib NA.

Hepatogastroenterology. 2005 Nov-Dec;52(66):1685-7.

PMID:
16334757
17.

A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model.

Burdío F, Navarro A, Berjano E, Sousa R, Burdío JM, Güemes A, Subiró J, Gonzalez A, Cruz I, Castiella T, Tejero E, Lozano R, Grande L, de Gregorio MA.

Eur J Surg Oncol. 2008 May;34(5):599-605. Epub 2007 Jul 5.

PMID:
17614248
18.

Bloodless liver resection using radiofrequency energy.

Ayav A, Jiao LR, Habib NA.

Dig Surg. 2007;24(4):314-7. Epub 2007 Jul 27.

PMID:
17657158
19.

Risks of the radiofrequency-assisted liver resection.

Tepetes K.

J Surg Oncol. 2008 Feb 1;97(2):193; author reply 194-5. doi: 10.1002/jso.20900. No abstract available.

PMID:
18181161
20.

Refining the technique of hepatic parenchymal transection: combined saline-linked radiofrequency precoagulation and ultrasonic aspiration.

Khan AZ, Bann SD, Pitsinis V, McCall J, Mudan SS.

Hepatogastroenterology. 2007 Jun;54(76):1167-9.

PMID:
17629063
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk