Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 372

1.

Effect on oximetry of dyes used for sentinel lymph node biopsy.

Piñero A, Illana J, García-Palenciano C, Cañizarese F, Canteras M, Cañadillas V, Durán E, Parilla P.

Arch Surg. 2004 Nov;139(11):1204-7.

PMID:
15546820
[PubMed - indexed for MEDLINE]
2.

Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.

El-Tamer M, Komenaka IK, Curry S, Troxel AB, Ditkoff BA, Schnabel FR.

Arch Surg. 2003 Nov;138(11):1257-60.

PMID:
14609878
[PubMed - indexed for MEDLINE]
3.

Factitious oxygen desaturation after isosulfan blue injection.

Heinle E, Burdumy T, Recabaren J.

Am Surg. 2003 Oct;69(10):899-901.

PMID:
14570371
[PubMed - indexed for MEDLINE]
4.

Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization.

Simmons RM, Smith SM, Osborne MP.

Breast J. 2001 May-Jun;7(3):181-3.

PMID:
11469932
[PubMed - indexed for MEDLINE]
5.

Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue.

Eldrageely K, Vargas MP, Khalkhali I, Venegas R, Burla M, Gonzalez KD, Vargas HI.

Am Surg. 2004 Oct;70(10):872-5.

PMID:
15529840
[PubMed - indexed for MEDLINE]
6.

Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.

Hoskin RW, Granger R.

Can J Anaesth. 2001 Jan;48(1):38-40.

PMID:
11212047
[PubMed - indexed for MEDLINE]
7.

A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.

Thevarajah S, Huston TL, Simmons RM.

Am J Surg. 2005 Feb;189(2):236-9. Review.

PMID:
15720998
[PubMed - indexed for MEDLINE]
8.

The role of sentinel lymph node biopsy with blue dye alone in breast cancer patients with excisional biopsy.

Asoglu O, Ozmen V, Karanlik H, Kecer M, Muzlumznoglu M, Igci A, Parlak M.

Acta Chir Belg. 2005 May-Jun;105(3):291-6.

PMID:
16018523
[PubMed - indexed for MEDLINE]
9.

Efficacy of methylene blue dye in localization of sentinel lymph node in breast cancer patients.

Nour A.

Breast J. 2004 Sep-Oct;10(5):388-91.

PMID:
15327490
[PubMed - indexed for MEDLINE]
10.

[False low oximetry reading caused by patent blue vital dye during breast surgery].

Nasif LA, Campos JM, Piñol S, Delgado MO, Casas JI, Landeira JM.

Rev Esp Anestesiol Reanim. 2005 Mar;52(3):169-71. Spanish.

PMID:
15850305
[PubMed - indexed for MEDLINE]
11.

Sentinel node mapping affects intraoperative pulse oximetric recordings during breast cancer surgery.

Koivusalo AM, Von Smitten K, Lindgren L.

Acta Anaesthesiol Scand. 2002 Apr;46(4):411-4.

PMID:
11952442
[PubMed - indexed for MEDLINE]
12.

A comparison of methylene blue and lymphazurin in breast cancer sentinel node mapping.

Blessing WD, Stolier AJ, Teng SC, Bolton JS, Fuhrman GM.

Am J Surg. 2002 Oct;184(4):341-5.

PMID:
12383897
[PubMed - indexed for MEDLINE]
13.

A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.

Aydogan F, Celik V, Uras C, Salihoglu Z, Topuz U.

Am J Surg. 2008 Feb;195(2):277-8. doi: 10.1016/j.amjsurg.2007.03.008. No abstract available.

PMID:
18194680
[PubMed - indexed for MEDLINE]
14.

Pulse oximetry and patent blue vital dye.

Lee BB.

Acta Anaesthesiol Scand. 2003 Apr;47(4):491; author reply 491. No abstract available.

PMID:
12694153
[PubMed - indexed for MEDLINE]
15.

Pulse oximetry declines due to intradermal isosulfan blue dye: a controlled prospective study.

Momeni R, Ariyan S.

Ann Surg Oncol. 2004 Apr;11(4):434-7.

PMID:
15070605
[PubMed - indexed for MEDLINE]
16.

[Exclusive use of blue dye to detect sentinel lymph nodes in breast cancer].

Bühler H S, Rojas P H, Cayazzo M D, Cunill C E, Vesperinas A G, Hamilton S J.

Rev Med Chil. 2008 Aug;136(8):1015-20. doi: /S0034-98872008000800008. Epub 2008 Oct 7. Spanish.

PMID:
18949185
[PubMed - indexed for MEDLINE]
Free Article
17.

[False decrease in pulse oximetry readings due to patent blue in a patient with breast cancer].

Murakami T, Kayo R, Kajita I, Cho S, Saito H.

Masui. 2003 Aug;52(8):909-11. Japanese.

PMID:
13677292
[PubMed - indexed for MEDLINE]
18.

The use of periareolar intradermal Tc-99m tin colloid and peritumoral intraparenchymal isosulfan blue dye injections for determination of the sentinel lymph node.

Argon AM, Duygun U, Acar E, Daglioz G, Yenjay L, Zekioglu O, Kapkac M.

Clin Nucl Med. 2006 Dec;31(12):795-800.

PMID:
17117076
[PubMed - indexed for MEDLINE]
19.

Isosulfan blue affects pulse oximetry.

Vokach-Brodsky L, Jeffrey SS, Lemmens HJ, Brock-Utne JG.

Anesthesiology. 2000 Oct;93(4):1002-3.

PMID:
11020754
[PubMed - indexed for MEDLINE]
20.

Methylene blue dye versus combined dye-radioactive tracer technique for sentinel lymph node localisation in early breast cancer.

Varghese P, Mostafa A, Abdel-Rahman AT, Akberali S, Gattuso J, Canizales A, Wells CA, Carpenter R.

Eur J Surg Oncol. 2007 Mar;33(2):147-52. Epub 2006 Oct 31.

PMID:
17081723
[PubMed - indexed for MEDLINE]