Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 216

Similar articles for PubMed (Select 11839878)

1.

Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise.

Watanabe I, Masaki R, Min N, Oshikawa N, Okubo K, Sugimura H, Kojima T, Saito S, Ozawa Y, Kanmatsuse K.

J Interv Card Electrophysiol. 2002 Feb;6(1):9-16.

PMID:
11839878
2.

Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation.

Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, McClelland JH, Lazzara R, Jackman WM.

Circulation. 1995 Apr 15;91(8):2264-73.

3.

Radiofrequency catheter ablation: different cooled and noncooled electrode systems induce specific lesion geometries and adverse effects profiles.

Dorwarth U, Fiek M, Remp T, Reithmann C, Dugas M, Steinbeck G, Hoffmann E.

Pacing Clin Electrophysiol. 2003 Jul;26(7 Pt 1):1438-45.

PMID:
12914619
4.

Advanced radiofrequency catheter ablation in canine myocardium.

Rosenbaum R, Greenspon AJ, Smith M, Walinsky P.

Am Heart J. 1994 Apr;127(4 Pt 1):851-7.

PMID:
8154424
5.

Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart.

Ruffy R, Imran MA, Santel DJ, Wharton JM.

J Cardiovasc Electrophysiol. 1995 Dec;6(12):1089-96.

PMID:
8720209
6.

Temperature-controlled cooled-tip radiofrequency ablation in left ventricular myocardium.

Watanabe I, Nuo M, Okumura Y, Ohkubo K, Ashino S, Kofune M, Kofune T, Nakai T, Kasamaki Y, Hirayama A.

Int Heart J. 2010 May;51(3):193-8.

7.

Catheter ablation of ventricular epicardial tissue: a comparison of standard and cooled-tip radiofrequency energy.

d'Avila A, Houghtaling C, Gutierrez P, Vragovic O, Ruskin JN, Josephson ME, Reddy VY.

Circulation. 2004 May 18;109(19):2363-9. Epub 2004 Apr 19.

8.

Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter.

Sapp JL, Cooper JM, Zei P, Stevenson WG.

J Cardiovasc Electrophysiol. 2006 Jun;17(6):657-61.

PMID:
16836718
10.

Epicardial radiofrequency ablation of ventricular myocardium: factors affecting lesion formation and damage to adjacent structures.

Fenelon G, Pereira KP, de Paola AA.

J Interv Card Electrophysiol. 2006 Jan;15(1):57-63.

PMID:
16680551
11.

Radiofrequency catheter ablation with the split-tip electrode in the temperature-controlled mode.

Antz M, Otomo K, Nakagawa H, Yamanashi WS, Jackman WM, Kuck KH.

Pacing Clin Electrophysiol. 2001 Dec;24(12):1765-73.

PMID:
11817810
12.
13.

Safety profiles and lesion size of different radiofrequency ablation technologies: a comparison of large tip, open and closed irrigation catheters.

Everett TH 4th, Lee KW, Wilson EE, Guerra JM, Varosy PD, Olgin JE.

J Cardiovasc Electrophysiol. 2009 Mar;20(3):325-35. doi: 10.1111/j.1540-8167.2008.01305.x. Epub 2008 Sep 17.

PMID:
18803562
14.

Discrepancies between catheter tip and tissue temperature in cooled-tip ablation: relevance to guiding left atrial ablation.

Bruce GK, Bunch TJ, Milton MA, Sarabanda A, Johnson SB, Packer DL.

Circulation. 2005 Aug 16;112(7):954-60. Epub 2005 Aug 8.

15.

Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.

Pilcher TA, Sanford AL, Saul JP, Haemmerich D.

Pacing Clin Electrophysiol. 2006 Dec;29(12):1368-74.

PMID:
17201844
16.

Popping phenomena in temperature-controlled radiofrequency ablation: when and why do they occur?

Eick OJ, Gerritse B, Schumacher B.

Pacing Clin Electrophysiol. 2000 Feb;23(2):253-8.

PMID:
10709234
17.

Comparison of a saline irrigated cooled-tip catheter to large electrode catheters with single and multiple temperature sensors for creation of large radiofrequency lesions.

McGreevy KS, Hummel JP, Jiangang Z, Haines DE.

J Interv Card Electrophysiol. 2005 Dec;14(3):139-45. Epub 2006 Jan 18.

PMID:
16421689
18.

Radiofrequency coagulation of ventricular myocardium: improved prediction of lesion size by monitoring catheter tip temperature.

Hindricks G, Haverkamp W, Gülker H, Rissel U, Budde T, Richter KD, Borggrefe M, Breithardt G.

Eur Heart J. 1989 Nov;10(11):972-84.

PMID:
2591398
20.

Ablation with an internally irrigated radiofrequency catheter: learning how to avoid steam pops.

Cooper JM, Sapp JL, Tedrow U, Pellegrini CP, Robinson D, Epstein LM, Stevenson WG.

Heart Rhythm. 2004 Sep;1(3):329-33.

PMID:
15851179
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk