Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 139

1.

Comparison of in vitro effectiveness of mechanical thrombectomy devices.

Müller-Hülsbeck S, Grimm J, Leidt J, Jahnke T, Heller M.

J Vasc Interv Radiol. 2001 Oct;12(10):1185-91.

PMID:
11585885
[PubMed - indexed for MEDLINE]
2.

In vitro effectiveness of mechanical thrombectomy devices for large vessel diameter and low-pressure fluid dynamic applications.

Müller-Hülsbeck S, Grimm J, Leidt J, Heller M.

J Vasc Interv Radiol. 2002 Aug;13(8):831-9.

PMID:
12171987
[PubMed - indexed for MEDLINE]
3.

[In-vitro comparison of the effectiveness of different high-speed rotatory catheters].

Müller-Hülsbeck S, Dimitte DN, Jahnke T, Hedderich J, Grimm J, Heller M.

Rofo. 2003 Mar;175(3):406-12. German.

PMID:
12635019
[PubMed - indexed for MEDLINE]
4.

In vitro effectiveness study of three hydrodynamic thrombectomy devices.

Müller-Hülsbeck S, Bangard C, Schwarzenberg H, Glüer CC, Heller M.

Radiology. 1999 May;211(2):433-9.

PMID:
10228525
[PubMed - indexed for MEDLINE]
5.

In vitro effectiveness study for hydrodynamic thrombectomy devices of the second generation.

Müller-Hülsbeck S, Schwarzenberg H, Bathe M, Lüsse S, Hutzelmann A, Heller M.

Invest Radiol. 1999 Jul;34(7):477-84.

PMID:
10399638
[PubMed - indexed for MEDLINE]
6.

Enhancement of in vitro effectiveness for hydrodynamic thrombectomy devices. Simultaneous high-pressure rt-PA application.

Müller-Hülsbeck S, Bathe M, Grimm J, Heller M.

Invest Radiol. 1999 Aug;34(8):536-42.

PMID:
10434186
[PubMed - indexed for MEDLINE]
7.

Mechanical assistance for enhancement of in vitro effectiveness for hydrodynamic thrombectomy.

Müller-Hülsbeck S, Grimm J, Suwelack D, Heller M.

Invest Radiol. 1999 Nov;34(11):669-77.

PMID:
10548378
[PubMed - indexed for MEDLINE]
8.

[In vitro comparison of a size 6F and 8F high-speed rotational catheter for mechanical thrombus fragmentation].

Müller-Hülsbeck S, Schwarzenberg H, Tschach T, Grimm J, Heller M.

Rofo. 1999 Jan;170(1):94-8. German.

PMID:
10071652
[PubMed - indexed for MEDLINE]
9.

Comparative in vitro study of two percutaneous hydrodynamic thrombectomy systems.

Bücker A, Schmitz-Rode T, Vorwerk D, Günther RW.

J Vasc Interv Radiol. 1996 May-Jun;7(3):445-9.

PMID:
8761830
[PubMed - indexed for MEDLINE]
10.

Influence of thrombus age on the mechanical thrombectomy efficacy of the amplatz thrombectomy device in vitro.

Grimm J, Jahnke T, Muhle C, Heller M, Müller-Hülsbeck S.

Cardiovasc Intervent Radiol. 2003 May-Jun;26(3):265-8.

PMID:
14562976
[PubMed - indexed for MEDLINE]
11.

Comparison of a new recirculation thrombectomy catheter with other devices of the same type: in vitro and in vivo evaluations.

Qian Z, Kvamme P, Raghed D, Maynar M, Hamide J, Scheer WD, Espinoza C, Loscertales B, Castañeda WR.

Invest Radiol. 2002 Sep;37(9):503-11.

PMID:
12218446
[PubMed - indexed for MEDLINE]
12.

[Suction pump-supported aspiration thrombectomy: an in-vitro comparison with a thrombus fragmentation procedure].

Müller-Hülsbeck S, Schwarzenberg H, Bangard C, Steffens JC, Heller M.

Rofo. 1998 Feb;168(2):191-4. German.

PMID:
9519054
[PubMed - indexed for MEDLINE]
13.

Declotting of embolized temporary vena cava filter by ultrasound and the Angiojet: comparative experimental in vitro studies.

Dick A, Neuerburg J, Schmitz-Rode T, Alliger H, Günther RW.

Invest Radiol. 1998 Feb;33(2):91-7.

PMID:
9493724
[PubMed - indexed for MEDLINE]
14.

In vitro evaluation of a rheolytic thrombectomy system for clot removal from five different temporary vena cava filters.

Buecker A, Neuerburg J, Schmitz-Rode T, Vorwerk D, Guenther RW.

Cardiovasc Intervent Radiol. 1997 Nov-Dec;20(6):448-51.

PMID:
9354714
[PubMed - indexed for MEDLINE]
15.

Percutaneous venous thrombectomy using the Arrow-Trerotola percutaneous thrombolytic device (PTD) with temporary caval filtration: in vitro investigations.

Wildberger JE, Haage P, Bovelander J, Pfeffer J, Weiss C, Vorwerk D, Schmitz-Rode T, Günther RW.

Cardiovasc Intervent Radiol. 2005 Mar-Apr;28(2):221-7.

PMID:
15883861
[PubMed - indexed for MEDLINE]
16.

Comparison of the mechanical thrombectomy efficacy of the Amplatz thrombectomy device and the Cragg thrombolytic brush in vitro.

Grimm J, Müller-Hülsbeck S, Heller M.

Invest Radiol. 2001 Apr;36(4):204-9.

PMID:
11283417
[PubMed - indexed for MEDLINE]
17.

Distal embolization during thrombectomy with use of the hydrolyser (hydrodynamic thrombectomy catheter): in vitro testing.

van Ommen VG, van der Veen FH, Dassen WR, Habets J, Wellens HJ.

J Vasc Interv Radiol. 1997 Nov-Dec;8(6):933-7.

PMID:
9399461
[PubMed - indexed for MEDLINE]
18.

Use of a temporary caval filter to assist percutaneous iliocaval thrombectomy: experimental results.

Vorwerk D, Schmitz-Rode T, Schürmann K, Tacke J, Guenther RW.

J Vasc Interv Radiol. 1995 Sep-Oct;6(5):737-40.

PMID:
8541677
[PubMed - indexed for MEDLINE]
19.

Acute and delayed outcomes of mechanical thrombectomy with use of the steerable Amplatz thrombectomy device in a model of subacute inferior vena cava thrombosis.

Gu X, Sharafuddin MJ, Titus JL, Urness M, Cervera-Ceballos JJ, Ruth GD, Amplatz K.

J Vasc Interv Radiol. 1997 Nov-Dec;8(6):947-56.

PMID:
9399463
[PubMed - indexed for MEDLINE]
20.

Mechanical thromboembolectomy for acute ischemic stroke: comparison of the catch thrombectomy device and the Merci Retriever in vivo.

Brekenfeld C, Schroth G, El-Koussy M, Nedeltchev K, Reinert M, Slotboom J, Gralla J.

Stroke. 2008 Apr;39(4):1213-9. doi: 10.1161/STROKEAHA.107.495614. Epub 2008 Feb 28.

PMID:
18309173
[PubMed - indexed for MEDLINE]
Free Article

Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk