Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 167

Similar articles for PubMed (Select 11524056)

1.

Vascular closure devices and the risk of vascular complications after percutaneous coronary intervention in patients receiving glycoprotein IIb-IIIa inhibitors.

Resnic FS, Blake GJ, Ohno-Machado L, Selwyn AP, Popma JJ, Rogers C.

Am J Cardiol. 2001 Sep 1;88(5):493-6.

PMID:
11524056
2.

Vascular Closure Devices: Technical Tips, Complications, and Management.

Krishnasamy VP, Hagar MJ, Scher DJ, Sanogo ML, Gabriel GE, Sarin SN.

Tech Vasc Interv Radiol. 2015 Jun;18(2):100-12. doi: 10.1053/j.tvir.2015.04.008. Epub 2015 Apr 11.

PMID:
26070622
3.

Bleeding Avoidance Strategies During Percutaneous Coronary Interventions.

Singh M.

J Am Coll Cardiol. 2015 May 26;65(20):2225-2238. doi: 10.1016/j.jacc.2015.03.567. Review.

PMID:
25998668
4.
5.

Where are we with vascular closure devices after percutaneous arteriotomy?

Cohen M.

J Invasive Cardiol. 2015 Mar;27(3):136-7. No abstract available.

6.

The data extraction and longitudinal trend analysis network study of distributed automated postmarket cardiovascular device safety surveillance.

Kumar A, Matheny ME, Ho KK, Yeh RW, Piemonte TC, Waldman H, Shah PB, Cope R, Normand SL, Donnelly S, Robbins S, Resnic FS.

Circ Cardiovasc Qual Outcomes. 2015 Jan;8(1):38-46. doi: 10.1161/CIRCOUTCOMES.114.001123. Epub 2014 Dec 9.

PMID:
25491915
7.

[Artery infections associated with percutaneous arterial closure devices: medico-legal issues].

Gaultier CJ, Houselstein T.

Ann Cardiol Angeiol (Paris). 2014 Dec;63(6):442-4. doi: 10.1016/j.ancard.2014.09.028. Epub 2014 Oct 1. French.

PMID:
25440766
8.

[Arterial Access Site Complications after Percutaneous Interventions with Special Regard to the Application of Vascular Closure Devices.]

Gratl A, Klocker J, Glodny B, Fraedrich G.

Zentralbl Chir. 2014 Oct 21. [Epub ahead of print] German.

PMID:
25333519
9.

Embolic complications induced by a vascular closure device.

Katoh M, Sugimura Y.

Intern Med. 2014;53(20):2405. Epub 2014 Oct 15. No abstract available.

10.

Large-scale experience with an anchorless vascular closure device in a real-life clinical setting.

Schelp V, Freitag-Wolf S, Hinzmann D, Bramlage P, Frey N, Frank D.

Clin Res Cardiol. 2015 Feb;104(2):145-53. doi: 10.1007/s00392-014-0766-3. Epub 2014 Oct 8.

PMID:
25293675
11.

Vascular complications of early (3 h) vs standard (6 h) ambulation post-cardiac catheterization or percutaneous coronary intervention from the femoral artery.

Kobrossi S, Tamim H, Dakik HA.

Int J Cardiol. 2014 Oct 20;176(3):1067-9. doi: 10.1016/j.ijcard.2014.07.137. Epub 2014 Aug 2.

PMID:
25175522
12.

Percutaneous closure of coronary fistulas in elderly patients with complex vascular anatomy.

Jiménez VA, Brooks J, Sepúlveda J, Ponce J, Baz JA, Iñiguez A.

Rev Esp Cardiol (Engl Ed). 2014 Sep;67(9):778-80. doi: 10.1016/j.rec.2014.04.006. Epub 2014 Jul 10. No abstract available.

PMID:
25172082
13.

Cost-effectiveness of contemporary vascular closure devices for the prevention of vascular complications after percutaneous coronary interventions in an all-comers PCI population.

Kerré S, Kustermans L, Vandendriessche T, Bosmans J, Haine SE, Miljoen H, Vrints CJ, Beutels P, Wouters K, Claeys MJ.

EuroIntervention. 2014 Jun;10(2):191-7. doi: 10.4244/EIJV10I2A32.

14.

Comparative safety of vascular closure devices.

Gurm HS, Hosman C, Hansen BB.

Ann Intern Med. 2014 Mar 18;160(6):438. doi: 10.7326/L14-5006-2. No abstract available.

PMID:
24723084
15.

Incidence and correlates in the development of iatrogenic femoral pseudoaneurysm after percutaneous coronary interventions.

Badr S, Kitabata H, Torguson R, Chen F, Suddath WO, Satler LF, Pichard AD, Waksman R, Bernardo NL.

J Interv Cardiol. 2014 Apr;27(2):212-6. doi: 10.1111/joic.12091. Epub 2014 Jan 22.

PMID:
24447166
16.

Comparative safety of vascular closure devices and manual closure among patients having percutaneous coronary intervention.

Gurm HS, Hosman C, Share D, Moscucci M, Hansen BB; Blue Cross Blue Shield of Michigan Cardiovascular Consortium.

Ann Intern Med. 2013 Nov 19;159(10):660-6. doi: 10.7326/0003-4819-159-10-201311190-00004.

PMID:
24247671
17.

Critical lower limb ischemia from an embolized Angio-Seal closure device.

Cianci C, Kowal RC, Feghali G, Hohmann S, Stoler RC, Choi JW.

Proc (Bayl Univ Med Cent). 2013 Oct;26(4):398-400.

18.

Retroperitoneal bleeding after cardiac catheterization: a 7-year descriptive single-center experience.

Eisen A, Kornowski R, Vaduganathan M, Lev E, Vaknin-Assa H, Bental T, Orvin K, Brosh D, Rechavia E, Battler A, Assali A.

Cardiology. 2013;125(4):217-22. doi: 10.1159/000351090. Epub 2013 Jun 20.

PMID:
23797048
19.

Meta-analysis of complication as a risk factor for early ambulation after percutaneous coronary intervention.

Kim K, Won S, Kim J, Lee E, Kim K, Park S.

Eur J Cardiovasc Nurs. 2013 Oct;12(5):429-36. doi: 10.1177/1474515112462519. Epub 2012 Oct 17. Review.

PMID:
23076977
20.

Vascular closure device failure in contemporary practice.

Vidi VD, Matheny ME, Govindarajulu US, Normand SL, Robbins SL, Agarwal VV, Bangalore S, Resnic FS.

JACC Cardiovasc Interv. 2012 Aug;5(8):837-44. doi: 10.1016/j.jcin.2012.05.005.

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content