Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 187

1.

The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.

Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW, Glyn-Jones S.

J Bone Joint Surg Am. 2011 Apr 20;93(8):716-22. doi: 10.2106/JBJS.J.00287.

PMID:
21508278
2.
3.

Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD.

J Bone Joint Surg Am. 2009 Apr;91(4):773-82. doi: 10.2106/JBJS.H.00244.

PMID:
19339560
4.

The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.

Glyn-Jones S, McLardy-Smith P, Gill HS, Murray DW.

J Bone Joint Surg Br. 2008 May;90(5):556-61. doi: 10.1302/0301-620X.90B5.20545.

PMID:
18450618
5.

The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.

Glyn-Jones S, Thomas GE, Garfjeld-Roberts P, Gundle R, Taylor A, McLardy-Smith P, Murray DW.

Clin Orthop Relat Res. 2015 Feb;473(2):432-8. doi: 10.1007/s11999-014-3735-2.

6.
7.

Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis.

Glyn-Jones S, Isaac S, Hauptfleisch J, McLardy-Smith P, Murray DW, Gill HS.

J Arthroplasty. 2008 Apr;23(3):337-43. doi: 10.1016/j.arth.2006.12.117.

PMID:
18358369
8.

Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study.

Campbell DG, Field JR, Callary SA.

Clin Orthop Relat Res. 2010 Oct;468(10):2704-9. doi: 10.1007/s11999-010-1259-y. Epub 2010 Feb 12.

9.

Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial.

van der Veen HC, van den Akker-Scheek I, Bulstra SK, van Raay JJ.

BMC Musculoskelet Disord. 2012 Sep 20;13:178. doi: 10.1186/1471-2474-13-178.

10.

Early outcomes of sequentially cross-linked thin polyethylene liners with large diameter femoral heads in total hip arthroplasty.

Sayeed SA, Mont MA, Costa CR, Johnson AJ, Naziri Q, Bonutti PM, Delanois RE.

Bull NYU Hosp Jt Dis. 2011;69 Suppl 1:S90-4.

11.

Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.

Hanna SA, Somerville L, McCalden RW, Naudie DD, MacDonald SJ.

Bone Joint J. 2016 Jan;98-B(1):28-32. doi: 10.1302/0301-620X.98B1.36527.

PMID:
26733512
12.

Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Karidakis GK, Karachalios T.

Clin Orthop Relat Res. 2015 Dec;473(12):3836-45. doi: 10.1007/s11999-015-4503-7.

PMID:
26290343
13.

A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components.

Langlois J, Atlan F, Scemama C, Courpied JP, Hamadouche M.

Bone Joint J. 2015 Nov;97-B(11):1458-62. doi: 10.1302/0301-620X.97B11.36219.

PMID:
26530645
14.

Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis.

Jonsson BA, Kadar T, Havelin LI, Haugan K, Espehaug B, Indrekvam K, Furnes O, Hallan G.

Bone Joint J. 2015 Nov;97-B(11):1463-9. doi: 10.1302/0301-620X.97B11.36137.

PMID:
26530646
15.

5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Digas G, Kärrholm J, Thanner J, Herberts P.

Acta Orthop. 2007 Dec;78(6):746-54. doi: 10.1080/17453670710014518.

PMID:
18236180
16.

Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years.

Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A.

J Bone Joint Surg Am. 2005 Aug;87(8):1816-21.

PMID:
16085624
18.

A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty.

Calvert GT, Devane PA, Fielden J, Adams K, Horne JG.

J Arthroplasty. 2009 Jun;24(4):505-10. doi: 10.1016/j.arth.2008.02.011. Epub 2008 Jun 10.

PMID:
18547784
19.

Does cross-linked polyethylene decrease the revision rate of total hip arthroplasty compared with conventional polyethylene? A meta-analysis.

Shen C, Tang ZH, Hu JZ, Zou GY, Xiao RC, Yan DX.

Orthop Traumatol Surg Res. 2014 Nov;100(7):745-50. doi: 10.1016/j.otsr.2014.07.015. Epub 2014 Oct 1. Review.

20.

Femoral Head Penetration of Vitamin E-Infused Highly Cross-Linked Polyethylene Liners: A Randomized Radiostereometric Study of Seventy Hips Followed for Two Years.

Shareghi B, Johanson PE, Kärrholm J.

J Bone Joint Surg Am. 2015 Aug 19;97(16):1366-71. doi: 10.2106/JBJS.N.00595.

PMID:
26290088
Items per page

Supplemental Content

Write to the Help Desk