Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 118

1.

The RABIT: a rapid automated biodosimetry tool for radiological triage.

Garty G, Chen Y, Salerno A, Turner H, Zhang J, Lyulko O, Bertucci A, Xu Y, Wang H, Simaan N, Randers-Pehrson G, Yao YL, Amundson SA, Brenner DJ.

Health Phys. 2010 Feb;98(2):209-17. doi: 10.1097/HP.0b013e3181ab3cb6.

2.

The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

Garty G, Chen Y, Turner HC, Zhang J, Lyulko OV, Bertucci A, Xu Y, Wang H, Simaan N, Randers-Pehrson G, Lawrence Yao Y, Brenner DJ.

Int J Radiat Biol. 2011 Aug;87(8):776-90. doi: 10.3109/09553002.2011.573612. Epub 2011 May 11.

3.

The RABiT: high-throughput technology for assessing global DSB repair.

Turner HC, Sharma P, Perrier JR, Bertucci A, Smilenov L, Johnson G, Taveras M, Brenner DJ, Garty G.

Radiat Environ Biophys. 2014 May;53(2):265-72. doi: 10.1007/s00411-014-0514-0. Epub 2014 Jan 30.

4.

Adapting the γ-H2AX assay for automated processing in human lymphocytes. 1. Technological aspects.

Turner HC, Brenner DJ, Chen Y, Bertucci A, Zhang J, Wang H, Lyulko OV, Xu Y, Shuryak I, Schaefer J, Simaan N, Randers-Pehrson G, Yao YL, Amundson SA, Garty G.

Radiat Res. 2011 Mar;175(3):282-90. doi: 10.1667/RR2125.1. Epub 2010 Dec 28.

5.

Triage dose assessment for partial-body exposure: dicentric analysis.

Prasanna PG, Moroni M, Pellmar TC.

Health Phys. 2010 Feb;98(2):244-51. doi: 10.1097/01.HP.0000348020.14969.4.

6.

Comparison of established and emerging biodosimetry assays.

Rothkamm K, Beinke C, Romm H, Badie C, Balagurunathan Y, Barnard S, Bernard N, Boulay-Greene H, Brengues M, De Amicis A, De Sanctis S, Greither R, Herodin F, Jones A, Kabacik S, Knie T, Kulka U, Lista F, Martigne P, Missel A, Moquet J, Oestreicher U, Peinnequin A, Poyot T, Roessler U, Scherthan H, Terbrueggen B, Thierens H, Valente M, Vral A, Zenhausern F, Meineke V, Braselmann H, Abend M.

Radiat Res. 2013 Aug;180(2):111-9. doi: 10.1667/RR3231.1. Epub 2013 Jul 17.

7.

Infrastructure to support ultra high throughput biodosimetry screening after a radiological event.

Garty G, Karam A, Brenner DJ.

Int J Radiat Biol. 2011 Aug;87(8):754-65. doi: 10.3109/09553002.2011.583317. Epub 2011 Jun 15.

8.

DESIGN AND PRELIMINARY VALIDATION OF A RAPID AUTOMATED BIODOSIMETRY TOOL FOR HIGH THROUGPUT RADIOLOGICAL TRIAGE.

Chen Y, Zhang J, Wang H, Garty G, Xu Y, Lyulko OV, Turner HC, Randers-Pehrson G, Simaan N, Yao YL, Brenner DJ.

Proc ASME Des Eng Tech Conf. 2009 Jan 1;3:61-67.

9.

Validation of the cytokinesis-block micronucleus (CBMN) assay for use as a triage biological dosimetry tool.

McNamee JP, Flegal FN, Greene HB, Marro L, Wilkins RC.

Radiat Prot Dosimetry. 2009 Aug;135(4):232-42. doi: 10.1093/rpd/ncp119.

PMID:
19628702
10.

An automated imaging system for radiation biodosimetry.

Garty G, Bigelow AW, Repin M, Turner HC, Bian D, Balajee AS, Lyulko OV, Taveras M, Yao YL, Brenner DJ.

Microsc Res Tech. 2015 Jul;78(7):587-98. doi: 10.1002/jemt.22512. Epub 2015 May 4.

11.

Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations.

Sullivan JM, Prasanna PG, Grace MB, Wathen LK, Wallace RL, Koerner JF, Coleman CN.

Health Phys. 2013 Dec;105(6):540-54. doi: 10.1097/HP.0b013e31829cf221.

12.

THE DECADE OF THE RABiT (2005-15).

Garty G, Turner HC, Salerno A, Bertucci A, Zhang J, Chen Y, Dutta A, Sharma P, Bian D, Taveras M, Wang H, Bhatla A, Balajee A, Bigelow AW, Repin M, Lyulko OV, Simaan N, Yao YL, Brenner DJ.

Radiat Prot Dosimetry. 2016 Jul 13. [Epub ahead of print]

PMID:
27412510
13.

In vitro RABiT measurement of dose rate effects on radiation induction of micronuclei in human peripheral blood lymphocytes.

Bertucci A, Smilenov LB, Turner HC, Amundson SA, Brenner DJ.

Radiat Environ Biophys. 2016 Mar;55(1):53-9. doi: 10.1007/s00411-015-0628-z. Epub 2016 Jan 20.

14.

Quickscan dicentric chromosome analysis for radiation biodosimetry.

Flegal FN, Devantier Y, McNamee JP, Wilkins RC.

Health Phys. 2010 Feb;98(2):276-81. doi: 10.1097/HP.0b013e3181aba9c7.

PMID:
20065694
15.

Validating high-throughput micronucleus analysis of peripheral reticulocytes for radiation biodosimetry: benchmark against dicentric and CBMN assays in a mouse model.

Chen Y, Tsai Y, Nowak I, Wang N, Hyrien O, Wilkins R, Ferrarotto C, Sun H, Dertinger SD.

Health Phys. 2010 Feb;98(2):218-27. doi: 10.1097/HP.0b013e3181abaae5.

PMID:
20065686
16.

Biodosimetry on small blood volume using gene expression assay.

Brengues M, Paap B, Bittner M, Amundson S, Seligmann B, Korn R, Lenigk R, Zenhausern F.

Health Phys. 2010 Feb;98(2):179-85. doi: 10.1097/01.HP.0000346706.44253.5c.

17.

Combined approach of hematological biomarkers and plasma protein SAA for improvement of radiation dose assessment triage in biodosimetry applications.

Ossetrova NI, Sandgren DJ, Gallego S, Blakely WF.

Health Phys. 2010 Feb;98(2):204-8. doi: 10.1097/HP.0b013e3181abaabf.

PMID:
20065684
18.

Laboratory intercomparison on the γ-H2AX foci assay.

Rothkamm K, Horn S, Scherthan H, Rössler U, De Amicis A, Barnard S, Kulka U, Lista F, Meineke V, Braselmann H, Beinke C, Abend M.

Radiat Res. 2013 Aug;180(2):149-55. doi: 10.1667/RR3238.1. Epub 2013 Jul 24.

PMID:
23883318
19.

Multi-parameter dose estimations in radiation biodosimetry using the automated cytokinesis-block micronucleus assay with imaging flow cytometry.

Rodrigues MA, Beaton-Green LA, Kutzner BC, Wilkins RC.

Cytometry A. 2014 Oct;85(10):883-93. doi: 10.1002/cyto.a.22511. Epub 2014 Aug 25.

20.

Laboratory intercomparison of the dicentric chromosome analysis assay.

Beinke C, Barnard S, Boulay-Greene H, De Amicis A, De Sanctis S, Herodin F, Jones A, Kulka U, Lista F, Lloyd D, Martigne P, Moquet J, Oestreicher U, Romm H, Rothkamm K, Valente M, Meineke V, Braselmann H, Abend M.

Radiat Res. 2013 Aug;180(2):129-37. doi: 10.1667/RR3235.1. Epub 2013 Jul 17.

PMID:
23862730
Items per page

Supplemental Content

Write to the Help Desk