    J Nucl Med. 1998 Sep;39(9):1536-41.

    Technetium-99m-furifosmin in the follow-up of differentiated thyroid carcinoma.

    Brandt-Mainz K, Müller SP, Sonnenschein W, Bockisch A.

    Klinik und Poliklinik für Nuklearmedizin, Universitätsklinikum Essen, Germany.

    Tumor scintigraphy with flow tracers, such as 201TI-chloride, has an established role in the follow-up of differentiated thyroid cancer. We investigated a new tracer, 99mTc-furifosmin (Technescan Q12, Mallinckrodt Diagnostika, Hennef, Germany), in patients with elevated thyroglobulin levels or sonographic suspicion of lymph node metastases or recurrent disease. METHODS: In a prospective study, we examined 20 patients with 99mTc-furifosmin. All patients underwent a 18F-fluorodeoxyglucose (FDG) PET scan of the neck and chest. Positive 99mTc-furifosmin findings were validated by biopsy, (131)I scan, CT or 18F-FDG PET examinations. RESULTS: In three patients with cervical lymph node metastases detected on a planar 99mTc-furifosmin scan, we found a rapid tracer accumulation in the tumor (maximum < 2 min) and a significant washout in 2 of 3 patients after 4 hr. The visual contrast and the tumor-to-nontumor ratio was rather poor (average 1.2:1). In 3 additional patients, 3 pulmonary and 2 mediastinal lymph node metastases were detected by the 99mTc-furifosmin SPECT scan. Two patients were true-negative, and in 13 of 18 patients, the tumor could be localized by 18F-FDG PET (10 cervical, 6 mediastinal, 4 pulmonary metastases, 1 bone metastasis); 5 patients were false-negative. In 3 of these false-negative cases we could not localize the tumor with other diagnostic methods. Two patients had a true-negative PET examination. CONCLUSION: The statistical analysis of our data on 99mTc-furifosmin reveals that the sensitivity and 95% confidence interval of 33% (11%-56%) on a patient-by-patient basis and of 34% (17%-57%) for the lesion-by-lesion analysis is significantly lower than the sensitivity and 95% confidence interval of 72% (50%-89%) on a patient-by-patient basis and of 91% (78%-100%) on lesion-by-lesion basis for 18F-FDG. The sensitivity of 99mTc-furifosmin appears to be poor, even for cervical and mediastinal tumor manifestations where the value of 201TI-chloride is established.

    PMID: 9744338 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read Click here to read Click here to read Click here to read

    Patient drug information

    • Thyroid (Armour® Thyroid)

      Thyroid is a hormone produced by the body. When taken correctly, thyroid is used to treat the symptoms of hypothyroidism (a condition where the thyroid gland does not produce enough thyroid hormone). Symptoms of hypothyr...