Display Settings:

Format

Send to:

Choose Destination
    Unfallchirurg. 1997 Aug;100(8):658-66.

    [Local foreign body reactions to biodegradable implants. A classification].

    [Article in German]

    Source

    Unfall- und Wiederherstellungschirurgie, Medizinische Fakultät Charité, Virchow Klinikum, Humboldt-Universität zu Berlin.

    Abstract

    Biodegradable implants are increasingly used in orthopedic and trauma surgery. Many different implants consisting of different biodegradable polymers are currently available. Different factors contribute to the biocompatibility of these implants, and local foreign-body reactions remain a matter of concern. Therefore, it is mandatory to document and compare the tissue reactions caused by various biodegradable implants in experimental or clinical studies. We have developed a standardized system of classification based on our previous experimental and clinical observations. Foreign-body reactions are differentiated into osteolysis (0-0 to 0-4), extra-articular (EA-0 to EA-4) and intraarticular (IA-0 to A-4) soft-tissue reactions.

    PMID:
    9381215
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for Springer

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk