Gastroenterology. 1997 Apr;112(4):1155-62.

[13C]octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility, and comparison with scintigraphy.

Author information

  • 1Gastroenterology Research Unit, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA.

Abstract

BACKGROUND & AIMS:

Previous work suggested that a breath test using 13C accurately measures gastric emptying of solids. Thus, breath test half emptying time (t1/2) minus 66 minutes was claimed to estimate accurately t1/2 by scintigraphy. The aim of this study was to evaluate the accuracy and reproducibility of this breath test in healthy subjects.

METHODS:

Fifteen volunteers (8 men and 7 women; mean age, 41 +/- 13 years) underwent simultaneous scintigraphy and [13C]octanoic acid breath test. Scans and breath samples were obtained every 15 minutes for 4 and 6 hours, respectively. The breath test was repeated three times within a 3-week period.

RESULTS:

Parameters from scintigraphy and breath test were not correlated significantly. Differences of lag phase and t1/2 between the two tests were highly variable (range for t1/2, -33.1 to 169.6; mean, 48.0 minutes). Increasing breath test "duration" (samples over 4, 5, or 6 hours) yielded decreasing estimates of the lag phase and t1/2. Although widely different values were observed in some subjects, repeated breath tests showed a high degree of reproducibility within individuals (mean coefficient of variation, 12%).

CONCLUSIONS:

[13C]Octanoic acid breath test for gastric emptying of solids requires further validation before it can substitute for scintigraphy as a diagnostic test, but it seems useful for intraindividual comparisons.

PMID:
9097998
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons