Display Settings:

Format

Send to:

Choose Destination
    JAMA. 1996 Sep 11;276(10):798-801.

    Preoperative autologous blood donations before elective hysterectomy.

    Source

    Kaiser Permanente Medical Center, Woodland Hills, CA, USA.

    Abstract

    OBJECTIVE:

    To determine whether preoperative autologous blood donation is justified for patients undergoing elective abdominal or vaginal hysterectomy.

    DESIGN:

    Retrospective cohort study.

    PATIENTS AND SETTING:

    A total of 263 consecutive patients admitted for elective abdominal or vaginal hysterectomy to a community health maintenance organization hospital during 1993 and 1994.

    MAIN OUTCOME MEASURES:

    Evaluation of transfusion rates for patients who did and did not donate autologous blood; determination of any risk factors that would predict the need for transfusion; and evaluation of the need for transfusion based on chart review.

    RESULTS:

    Of 263 patients, 26 received a blood transfusion. The major risk factor identified for transfusion was the donation of autologous blood. Of 140 patients who donated autologous blood, 25 were transfused, whereas just 1 patient of 123 who did not donate autologous blood was transfused (P<.001). Patients who donated autologous blood had significantly lower mean admission hemoglobin level than patients who did not donate (119 g/L vs 132 g/L; P<.05); logistic regression showed that autologous donation was an independent risk factor for transfusion.

    CONCLUSION:

    For hysterectomy patients, donation of autologous blood causes anemia and is associated with a more liberal transfusion policy. These 2 factors result in a markedly increased incidence of transfusion with its associated risks. Elimination of preoperative autologous donation for these patients should not result in frequent exposure to allogeneic blood.