Dialysis hypoxemia. Role of dialyzer membrane and dialysate delivery system

Am J Med. 1984 Nov;77(5):828-33. doi: 10.1016/0002-9343(84)90519-9.

Abstract

Arterial blood gas values, carbon monoxide diffusion capacity, oxygen consumption, carbon dioxide production, respiratory quotient, minute ventilation, and pulmonary capillary blood flow were determined before and during hemodialysis. In addition, the effect of single passage through the dialyzer on blood carbon dioxide tension, pH, and bicarbonate concentration was evaluated. Acetate-based dialysate was used in all experiments. Cellulosic dialyzer with single-pass dialysate delivery system was used in one group, and polyacrylonitrile dialyzers with recirculating delivery system in another. Although hypoxemia occurred in both groups, it was more severe in the former group. Dialyzer carbon dioxide loss was significantly greater with single-pass dialysate delivery system and cellulosic dialyzers than with recirculating delivery system and polyacrylonitrile dialyzer. To differentiate the role of dialysate delivery system from that of the membrane, the experiments were repeated using recirculating delivery system and cellulosic dialyzer. This resulted in marked attenuation of hypoxemia and dialyzer carbon dioxide tension losses. Since other experimental conditions were the same, the observed differences were thought to be due to the difference in the mode of dialysate delivery. It thus appears that the mode of dialysate delivery per se can modify the changes in arterial oxygen tension during hemodialysis and should be added to the list of factors implicated in the genesis of dialysis hypoxemia.

MeSH terms

  • Acrylic Resins
  • Adult
  • Aged
  • Blood Gas Analysis
  • Cellulose
  • Female
  • Humans
  • Hypoxia / etiology*
  • Male
  • Middle Aged
  • Oxygen Consumption
  • Renal Dialysis / adverse effects*
  • Renal Dialysis / methods

Substances

  • Acrylic Resins
  • polyacrylonitrile
  • Cellulose