Z Lebensm Unters Forsch. 1985 Mar;180(3):211-4.

Determination of furazolidone residues in eggs by HPLC followed by confirmation with a diode-array UV/Vis detector.

Abstract

A sensitive HPLC method for the determination of furazolidone residues in eggs (10-1,000 micrograms/kg) is described. Recovery is about 86%. With the aid of a UV/Vis Diode-Array detector confirmation up to the 15-ppb level was possible. In order to test this method with "real" samples, three laying hens received 30 mg each of furazolidone in feed (single dose). The eggs were collected for five days. After five days traces of furazolidone (5 micrograms/kg) could still be detected.