Effect of milk flow-rate switch-point settings on milking duration and udder health throughout lactation

J Dairy Sci. 2023 Dec;106(12):8861-8870. doi: 10.3168/jds.2023-23559. Epub 2023 Aug 23.

Abstract

The objective of this study was to quantify the effects of different milk flow-rate switch-point settings on milking duration, somatic cell count (SCC), strip milk, teat condition, and milk yield in a grass-based system in a long-term experiment. Much work has already been conducted providing strong support for significant reduction in milking duration without effects on yield through increasing the flow-rate switch-point at which vacuum to the milking cluster ceases and the cluster is removed from the cow by means of a retracting cord. However, in practice many farms have not adopted this labor-saving technology on the basis that it may increase milk SCC. Recent research on commercial Irish dairy herds identified the contagious mastitis-causing pathogen Staphylococcus. aureus as the most prevalent pathogen detected. Staph. aureus could have a cyclical shedding pattern which would inhibit detection at certain time points. Therefore, to reliably assess the effect of milk flow-rate switch-points on SCC, a long-term study was required, consisting of multiple observations on cow-level SCC. The present study filled this gap in knowledge by informing on any effect that ceasing milking at different flow rates may have on milking duration and SCC levels, particularly with regard to spring calving grass-based systems. Four treatments, consisting of milk flow-rate switch-points increasing from 0.2 kg/min to 0.8 kg/min in steps of 0.2 kg/min, were deployed for 31 wk to cows at the Teagasc Research Centre at Moorepark, Ireland. The effect of treatment on daily milking duration was significant. The milking duration for a milk flow-rate switch-point of 0.8 kg/min was 95 s (14%) shorter than for 0.2 kg/min. We did not find a significant effect of increasing the milk flow-rate switch-point from 0.2 to 0.8 kg/min on milk yield or SCC in this long-term study. We did find a significant effect of week of experiment on milk SCC, whereby the SCC of the cows on the experiment increased similarly among treatment groups as lactation progressed. A significant reduction in dead time (time from cluster attachment to reach a milk flow rate of 0.2 kg/min) was also noted as the milk flow-rate switch-point increased. On average, reductions in dead time contributed 12% to the overall reductions in milking duration. Similarly, reductions in low flow time (time from a flow rate of 0.2 kg/min to cluster detachment at the end of milking) contributed 26% to the overall reductions in milking duration. Reductions in dead time and low flow time played a greater role in reducing p.m. milking duration rather than a.m. milking duration due to the milking interval practiced on the research farm.

Keywords: cluster removers; cow comfort; milking; milking efficiency.

MeSH terms

  • Animals
  • Cattle
  • Cell Count / veterinary
  • Dairying
  • Female
  • Lactation
  • Mammary Glands, Animal*
  • Milk*
  • Time Factors