Frequency of prothrombin time-international normalized ratio monitoring and the long-term prognosis in patients with mechanical valve replacement

BMC Cardiovasc Disord. 2023 Jun 24;23(1):322. doi: 10.1186/s12872-023-03293-w.

Abstract

Background: The study aimed to assess the correlation between the monitoring frequency of PT-INR and the long-term prognosis in patients with mechanical heart valve (MHV) replacement after discharge.

Methods: This single-center, observational study enrolled patients who underwent MHV replacement and discharged from June 2015 to May 2018. Patients or their corresponding family members were followed with a telephone questionnaire survey in July-October 2020. Based on monitoring intervals, patients were divided into frequent monitoring (FM) group (≤ 1 month) and less frequent monitoring (LFM) group (> 1 month). The primary endpoint was the composite of thromboembolic event, major bleeding or all-cause death. The secondary endpoints were thromboembolic event, major bleeding or all-cause death, respectively.

Results: A total of 188 patients were included in the final analysis. The median follow-up duration was 3.6 years (Interquartile range: 2.6 to 4.4 years). 104 (55.3%) patients and 84 (44.7%) patients were classified into the FM group and the LFM group, respectively. The FM group had a significantly lower incidence of the primary endpoint than the LFM group (3.74 vs. 1.16 per 100 patient-years, adjusted HR: 3.31 [95% CI 1.05-10.42, P = 0.041]). Secondary analysis revealed that the risk of thromboembolic events and all-cause death were also reduced in the FM group.

Conclusions: The management of warfarin treatment in patients after MHV replacement remains challenging. Patients with less frequent monitoring of PT-INR might have worse clinical prognosis than those with frequent PT-INR monitoring.

Keywords: Mechanical heart valve; Monitoring frequency; Prothrombin time-international normalized ratio; Warfarin.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anticoagulants / adverse effects
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Hemorrhage / chemically induced
  • Humans
  • International Normalized Ratio / adverse effects
  • Prognosis
  • Prothrombin Time
  • Risk Factors
  • Thromboembolism* / etiology
  • Thromboembolism* / prevention & control
  • Warfarin / adverse effects

Substances

  • Warfarin
  • Anticoagulants