Near vacuum-ultraviolet aperiodic oscillation emission of AlN films

Sci Bull (Beijing). 2020 May 30;65(10):827-831. doi: 10.1016/j.scib.2020.02.018. Epub 2020 Feb 20.

Abstract

An accurate measurement of the refractive index is necessary for the optical design of both deep ultraviolet laser diodes and light-emitting diodes. Generally, the refractive indices along different crystallographic axes of anisotropic thin films are measured using variable angle spectroscopic ellipsometry. However, there are still some limitations concerning this method. Here we proposed a potential method to measure the band edge refractive index of wide bandgap semiconductor. An aperiodic oscillation emission phenomenon due to the Fabry-Perot effect was observed in the fluorescence spectrum of an AlN film with a thickness of 1500 nm. Based on the characteristics of the fluorescence spectrum and the definition of Fabry-Perot effect, we obtained the ordinary refractive index of the AlN thin film near the band edge directly. This refractive index measurement method is a supplement to the variable angle ellipsometry, and it is a more direct and effective method for transferred film and thinner samples to measure the fluorescence spectrum.

Keywords: AlN; Ellipsometer; Fluorescence spectrum; Refractive index.