Free-breathing 3D stack-of-radial MRI quantification of liver fat and R2* in adults with fatty liver disease

Magn Reson Imaging. 2022 Jan:85:141-152. doi: 10.1016/j.mri.2021.10.016. Epub 2021 Oct 16.

Abstract

Purpose: To investigate the agreement, intra-session repeatability, and inter-reader agreement of liver proton-density fat fraction (PDFF) and R2* quantification using free-breathing 3D stack-of-radial MRI, with and without self-gated motion compensation, compared to reference breath-hold techniques in subjects with fatty liver disease (FLD).

Methods: In this institutional review board-approved prospective study, thirty-eight adults with FLD and/or iron overload (24 male, 58 ± 12 years) were imaged at 3T using free-breathing stack-of-radial MRI, breath-hold 3D Cartesian MRI, and breath-hold single-voxel MR spectroscopy (SVS). Each sequence was acquired twice in random order. To assess agreement compared to reference breath-hold techniques, the dependency of liver PDFF and/or R2* quantification on the sequence, radial sampling factor, and radial self-gating temporal resolution was assessed by calculating the Bayesian mean difference (MDB) of the posteriors. Intra-session repeatability and inter-reader agreement (two independent readers) were assessed by the coefficient of repeatability (CR) and intraclass correlation coefficient (ICC), respectively.

Results: Thirty-five participants (21 male, 57 ± 12 years) were included for analysis. Both free-breathing radial MRI techniques (with and without self-gating) achieved ICC ≥ 0.92 for quantifying PDFF and R2*, and quantified PDFF with MDB < 1.2% compared to breath-hold techniques. Free-breathing radial MRI required self-gating to accurately quantify R2* (MDB < 10s-1 with self-gating; MDB < 50s-1 without self-gating). The radial sampling factor affected PDFF and R2* quantification while the radial self-gating temporal resolution only affected R2* quantification. Repeated self-gated free-breathing radial MRI scans achieved CR < 3% and CR < 27 s-1 for PDFF and R2*, respectively.

Conclusion: A free-breathing stack-of-radial MRI technique with self-gating demonstrated agreement, repeatability, and inter-reader agreement compared to reference breath-hold techniques for quantification of liver PDFF and R2* in adults with FLD.

Keywords: Fatty liver disease; Free-breathing MRI; Motion compensation; Proton-density fat fraction; R(2)*; Radial MRI; Self-gating.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Bayes Theorem
  • Humans
  • Liver / diagnostic imaging
  • Magnetic Resonance Imaging* / methods
  • Male
  • Non-alcoholic Fatty Liver Disease* / diagnostic imaging
  • Prospective Studies