Optimizing the Use of High-Sensitivity Troponin Assays for the Early Rule-out of Myocardial Infarction in Patients Presenting with Chest Pain: A Systematic Review

Clin Chem. 2021 Jan 8;67(1):237-244. doi: 10.1093/clinchem/hvaa280.

Abstract

Background: We assessed the accuracy and clinical effectiveness of high-sensitivity cardiac troponin (hs-cTn) assays for early rule-out of non-ST-segment elevation myocardial infarction (NSTEMI) in adults presenting with acute chest pain.

Methods: Sixteen databases were searched to September 2019. Review methods followed published guidelines. The bivariate model was used to estimate summary sensitivity and specificity with 95% confidence intervals for meta-analyses involving 4 or more studies, otherwise random-effects logistic regression was used.

Results: Thirty-seven studies (124 publications) were included in the review. The hs-cTn test strategies evaluated in the included studies were defined by the combination of 4 factors (assay, number of tests, timing of tests, and threshold concentration or change in concentration between tests). Clinical opinion indicated a minimum acceptable sensitivity of 97%. A single test at presentation using a threshold at or near the assay limit of detection could reliably rule-out NSTEMI for a range of hs-cTn assays. Serial testing strategies, which include an immediate rule-out step, increased the proportion ruled out without loss of sensitivity. Finally, serial testing strategies without an immediate rule-out step had excellent sensitivity and specificity, but at the expense of the option for immediate patient discharge.

Conclusion: Test strategies that comprise an initial rule-out step, based on low hs-cTn concentrations at presentation and a minimum symptom duration, and a second step for those not ruled-out that incorporates a small absolute change in hs-cTn at 1, 2, or 3 hours, produce the highest rule-out rates with a very low risk of missed NSTEMI.

Prospero registration: CRD42019154716.

Publication types

  • Research Support, Non-U.S. Gov't
  • Systematic Review

MeSH terms

  • Adult
  • Algorithms
  • Angina Pectoris / blood*
  • Angina Pectoris / complications
  • Diagnostic Tests, Routine / methods
  • Humans
  • Non-ST Elevated Myocardial Infarction / blood
  • Non-ST Elevated Myocardial Infarction / complications
  • Non-ST Elevated Myocardial Infarction / diagnosis*
  • Randomized Controlled Trials as Topic
  • Sensitivity and Specificity
  • Troponin I / analysis*
  • Troponin T / analysis*

Substances

  • Troponin I
  • Troponin T