Lightweight mesh is recommended in open inguinal (Lichtenstein) hernia repair: A systematic review and meta-analysis

Surgery. 2020 Mar;167(3):581-589. doi: 10.1016/j.surg.2019.08.021. Epub 2019 Oct 28.

Abstract

Background: The use of lightweight mesh for inguinal hernia repair has been suggested to be preferable compared with heavyweight mesh. Nevertheless, surgeons do not use lightweight mesh routinely, possibly owing to the higher price and lack of confidence in evaluation of previous evidence. The aim of this systematic review and meta-analysis is to update the available randomized controlled trials and provide a recommendation on the use of lightweight mesh or heavyweight mesh in open inguinal hernia repair.

Methods: A literature search was conducted in May 2019 in MEDLINE, Embase and the Cochrane library for randomized controlled trials comparing lightweight (≤50 g/m2) and heavyweight (>70 g/m2) mesh in patients undergoing open (Lichtenstein) surgery for uncomplicated inguinal hernias. Outcomes were recurrences (overall, after direct or indirect repair), chronic pain (analyzing any and severe pain), and the feeling of a foreign body. The level of evidence was assessed using GRADE. Risk ratios and 95% confidence intervals were calculated by random effect meta-analyses.

Results: Twenty-one randomized controlled trials involving 4,576 patients (lightweight mesh 2,257 vs heavyweight mesh 2,319) were included. Follow-up ranged from 3 to 60 months. No difference between lightweight mesh and heavyweight mesh was determined for recurrence rates (lightweight mesh 42 of 2,068 and heavyweight mesh 34 of 2,132; risk ratios 1.22; 95% confidence interval, 0.76-1.96) or severe pain (lightweight mesh 14 of 1,517 and heavyweight mesh 26 of 1,591; risk ratios 0.73; 95% confidence interval, 0.38-1.41). A significant reduction was seen for any pain after lightweight mesh (234 of 1,603) compared with heavyweight mesh (322 of 1,683; risk ratios 0.78; 95% confidence interval, 0.64-0.96) and for the feeling of a foreign body (lightweight mesh 130 of 1,053 and heavyweight mesh 209 of 1,035; risk ratios 0.64; 95% confidence interval, 0.51-0.80).

Conclusion: Lightweight mesh should be used in open (Lichtenstein) inguinal hernia repair.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Chronic Pain / diagnosis
  • Chronic Pain / epidemiology*
  • Chronic Pain / etiology
  • Chronic Pain / prevention & control
  • Hernia, Inguinal / surgery*
  • Herniorrhaphy / adverse effects*
  • Herniorrhaphy / instrumentation
  • Herniorrhaphy / methods
  • Humans
  • Pain Measurement
  • Pain, Postoperative / diagnosis
  • Pain, Postoperative / epidemiology*
  • Pain, Postoperative / etiology
  • Pain, Postoperative / prevention & control
  • Randomized Controlled Trials as Topic
  • Recurrence
  • Surgical Mesh / adverse effects*
  • Treatment Outcome