Amplified oxygen reduction signal at a Pt-Sn-modified TiO2 nanocomposite on an electrochemical aptasensor

Biosens Bioelectron. 2019 Oct 1:142:111525. doi: 10.1016/j.bios.2019.111525. Epub 2019 Jul 23.

Abstract

In this work, a metallic composite with strong electrocatalytic property was designed by uniformly decorating Pt and Sn nanoparticles on the surface of TiO2 nanorods (Pt-Sn@TiO2). A detection scheme was then developed based on a dual signal amplification strategy involving the Pt-Sn@TiO2 composite and exonuclease assisted target recycling. The Pt-Sn@TiO2 composite exhibited an enhanced oxygen reduction current owing to the synergistic effect between Pt and Sn, as well as high exposure of Pt (111) crystal face. Initially, a Pt-Sn@TiO2 modified glassy carbon electrode produced an amplified electrochemical signal for the reduction of dissolved oxygen in the analyte solution. Next, a DNA with a complementary sequence to a streptomycin aptamer (cDNA) was immobilised on the Pt-Sn@TiO2 modified electrode, followed by the streptomycin aptamer that hybridised with cDNA. The corresponding oxygen reduction current was diminished by 51% attributable to the hindrance from the biomolecules. After a mixture of streptomycin and RecJf exonuclease was introduced, both the streptomycin-aptamer complex and the cDNA were cleaved from the electrode, making the Pt-Sn and Pt (111) surface available for oxygen reduction. RecJf would also release streptomycin from the streptomycin-aptamer complex, allowing it to complex again with aptamers on the electrode. This has then promoted a cyclic amplification of the oxygen reduction current by 85%, which is quantitatively related to streptomycin. Under optimal conditions, the aptasensor exhibited a linear range of 0.05-1500 nM and a limit of detection of 0.02±0.0045 nM streptomycin. The sensor was then used in the real-life sample detection of streptomycin to demonstrate its potential applications to bioanalysis.

Keywords: Electrochemical aptasensor; Oxygen reduction reaction; Pt-Sn@TiO(2) composite; RecJ(f) exonuclease; Streptomycin.

Publication types

  • Evaluation Study

MeSH terms

  • Animals
  • Anti-Bacterial Agents / analysis*
  • Aptamers, Nucleotide / chemistry*
  • Biosensing Techniques / instrumentation*
  • Electrochemical Techniques / instrumentation
  • Equipment Design
  • Food Analysis / instrumentation
  • Limit of Detection
  • Milk / chemistry
  • Nanocomposites / chemistry*
  • Nanocomposites / ultrastructure
  • Oxidation-Reduction
  • Oxygen / chemistry
  • Platinum / chemistry
  • Streptomycin / analysis*
  • Tin / chemistry
  • Titanium / chemistry*

Substances

  • Anti-Bacterial Agents
  • Aptamers, Nucleotide
  • titanium dioxide
  • Platinum
  • Tin
  • Titanium
  • Oxygen
  • Streptomycin