Significance and Risk Factors for Intraprosthetic Mural Thrombus in Abdominal Aortic Endografts: A Systematic Review and Meta-analysis

Ann Vasc Surg. 2018 Nov:53:234-242. doi: 10.1016/j.avsg.2018.04.027. Epub 2018 Aug 9.

Abstract

Background: The detection of intraprosthetic thrombus (IPT) deposits is a common finding during follow-up for endovascular abdominal aneurysm repair (EVAR); however, its clinical significance is still debated. The aim of this study was to determine if IPT represents a risk factor for thromboembolic events (TEs; endograft or limb thrombosis, or distal embolization) after EVAR.

Methods: A systematic review of English literature was undertaken until November 2017. Studies providing 2-group comparison (patients with IPT development on postoperative computed tomography angiography versus patients without IPT) with extractable outcome data (TE related to IPT and/or risk factors for IPT development) were included. Meta-analysis was performed when comparative data were given in 2 or more articles.

Results: Five single-center studies (808 patients) were analyzed. IPT detection at any time during follow-up occurred in 20.8% (168/808) of patients. Extractable data for postoperative TE were available in 4 studies (613 patients): on comparative meta-analysis, IPT was not significantly associated with TE occurrence during follow-up (odds ratio 2.25, 95% confidence interval [CI] 0.50-10.1; P = 0.29). IPT is generally detected during the first year after EVAR (maximum reported median: 12 months, range: 1.2-23). Polyester graft material (odds ratio 2.34, 95% CI 1.53-3.58; P < 0.001) and aorto-uni-iliac configuration of the endograft (odds ratio 3.27, 95% CI 1.66-6.44; P = 0.001) were confirmed as risk factors for IPT formation on meta-analysis. The literature systematic review suggests that IPT formation may be also associated with long main bodies and large necks.

Conclusions: IPT detection on postoperative computed tomography angiography was not significantly associated with the occurrence of TE over time. The aorto-uni-iliac configuration and the use of polyester fabric for endografts were confirmed as risk factors for IPT development.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / physiopathology
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis / adverse effects*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Blood Vessel Prosthesis Implantation / instrumentation
  • Computed Tomography Angiography
  • Endovascular Procedures / adverse effects*
  • Endovascular Procedures / instrumentation
  • Female
  • Graft Occlusion, Vascular / diagnostic imaging
  • Graft Occlusion, Vascular / etiology*
  • Graft Occlusion, Vascular / physiopathology
  • Humans
  • Male
  • Middle Aged
  • Polyesters / adverse effects
  • Prosthesis Design
  • Risk Factors
  • Stents / adverse effects*
  • Thrombosis / diagnostic imaging
  • Thrombosis / etiology*
  • Thrombosis / physiopathology
  • Time Factors
  • Treatment Outcome

Substances

  • Polyesters