Test-retest reliability of two-dimensional video analysis during running

Phys Ther Sport. 2018 Sep:33:40-47. doi: 10.1016/j.ptsp.2018.06.009. Epub 2018 Jun 30.

Abstract

Objectives: To examine test-retest reliability of two-dimensional measured frontal and sagittal plane kinematics during running, and to determine how many steps to include to reach and maintain a stable mean.

Design: Reliability study.

Setting: Research laboratory.

Participants: Twenty-one recreational runners.

Main outcome measures: Lateral trunk position, contralateral pelvic drop, femoral adduction, hip adduction, knee flexion and ankle dorsiflexion during midstance, and foot and tibia inclination at initial contact were measured with two-dimensional video analysis during running for 10 consecutive steps for both legs. All participants were tested twice one week apart. A sequential estimation method was used to determine the number of steps needed to reach a stable mean. Intraclass correlation coefficients (ICC) and smallest detectable differences (SDD) were calculated.

Results: The minimal number of steps was 6.3 ± 0.3. Lateral trunk position, femoral adduction and foot inclination showed excellent reliability (ICC 0.90-0.99; SDD 1.3°-2.3°). Tibia inclination and ankle dorsiflexion showed good to excellent reliability (ICC 0.73-0.92; SDD 2.2°-4.8°). Hip adduction and knee flexion showed good reliability (ICC 0.82-0.89; SDD 2.3°-3.8°). Contralateral pelvic drop showed moderate to good reliability (ICC 0.59-0.77; SDD 2.7°-2.8°).

Conclusion: Two-dimensional video analysis is reliable to assess running kinematics on different days. The mean of at least 7 steps should be included.

Keywords: Kinematics; Reliability; Running; Two-dimensional video analysis.

MeSH terms

  • Adult
  • Biomechanical Phenomena
  • Female
  • Foot
  • Gait*
  • Humans
  • Male
  • Pelvis
  • Reproducibility of Results
  • Running / physiology*
  • Tibia
  • Torso
  • Video Recording*
  • Young Adult