    J Chromatogr. 1978 Sep 1;146(2):311-20.

    Analysis of lorazepam and its glucuronide metabolite by electron-capture gas--liquid chromatography. Use in pharmacokinetic studies of lorazepam.

    Abstract

    This paper describes a rapid and sensitive method for analysis of lorazepam and its glucuronide metabolite in plasma and urine following therapeutic doses of lorazepam in humans. After addition of the structurally related benzodiazepine derivative, oxazepam, as the internal standard, 1-ml samples of plasma or urine are extracted twice at neutral pH with benzene (containing 1.5% isoamyl alcohol). The combined extracts are evaporated to dryness, reconstituted, and subjected to gas chromatographic analysis using a 3% OV-17 column and an electron-capture detector. Lorazepam glucuronide in urine is similarly analyzed following enzymatic cleavage with Glusulase. The sensitivity limits are 1--3 ng of analyzed following enzymatic cleavage with Glusulase. The sensitivity limits are 1--3 ng of lorazepam per ml of original sample, and the variability of identical samples is 5% or less. The applicability of the method to pharmacokinetic studies of lorazepam is demonstrated.