Three-Year Results of the Endurant Stent Graft System Post Approval Study

Ann Vasc Surg. 2018 Jul:50:202-208. doi: 10.1016/j.avsg.2017.12.017. Epub 2018 Mar 2.

Abstract

Background: Long-term data following endovascular aneurysm repair (EVAR) exist but are limited to endografts that are no longer in use. The aim of the ENGAGE Post Approval Study is to describe the long-term safety and effectiveness data following EVAR using the Endurant stent graft system.

Methods: From August 2011 to June 2012, 178 patients were enrolled and treated with the Endurant stent graft system. Clinical and radiologic data were prospectively collected and analyzed. The primary end point was abdominal aortic aneurysm (AAA)-related mortality, and secondary end points were overall mortality, endoleak, secondary interventions, and device-related complications. Kaplan-Meier estimates were used for late outcomes.

Results: A total of 178 patients underwent EVAR with the Endurant stent graft across 24 centers (82% men; median age 71, interquartile range [IQR] 66-79). Median aortic diameter was 55 mm (IQR 51-58 mm). There was a 98.9% technical success rate. Three-year clinical and radiographic follow-up data were available for 87% and 74% of patients, respectively. Median follow-up was 37 months (IQR 30-38 months). Three-year aneurysm-related mortality rate was 1.1%, with 2 deceased patients in the perioperative period. All-cause mortality rate at 3 years was 13%. No patients suffered from aneurysm rupture or underwent conversion to open repair through 3 years of follow-up. Only 11 patients (6.2%) had undergone reintervention at 3 years. Younger age was associated with reintervention (HR 3.3 per younger decade, 95% confidence interval 1.3-7.6, P < 0.01), but neck diameter, length, and angulation were not significantly associated with reintervention.

Conclusions: The Endurant stent graft system provides a safe, durable approach to treating infrarenal AAA. No patients experienced late rupture or aneurysm-related mortality, and only 1 in 16 patients underwent reintervention by 3 years. The rate of reintervention with the Endurant graft appears to be lower than other contemporary grafts, despite more liberal "Instructions For Use" parameters, but further research including direct graft comparisons will be necessary to guide appropriate graft selection.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / mortality
  • Aortic Aneurysm, Abdominal / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis Implantation / mortality
  • Blood Vessel Prosthesis*
  • Endoleak / etiology
  • Endoleak / therapy
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Endovascular Procedures / mortality
  • Female
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Product Surveillance, Postmarketing
  • Proportional Hazards Models
  • Prospective Studies
  • Prosthesis Design
  • Retreatment
  • Stents*
  • Time Factors
  • Treatment Outcome
  • United States