The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA

J Orthop Surg (Hong Kong). 2017 Sep-Dec;25(3):2309499017731626. doi: 10.1177/2309499017731626.

Abstract

Introduction: Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application.

Materials and methods: This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed.

Results: We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p < 0.001). There was no significant difference between groups B and C ( p = 0.99).

Conclusions: The drainage clamping method can be safer than IA-TXA administration in patients with risk factor of venous thromboembolic complication. Furthermore, the IA-TXA administration can be more optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

Keywords: blood loss; drain clamping; total knee replacement; tranexamic acid; transfusion.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Antifibrinolytic Agents / administration & dosage*
  • Arthroplasty, Replacement, Knee*
  • Blood Loss, Surgical / prevention & control
  • Blood Transfusion*
  • Clinical Protocols / standards
  • Constriction
  • Drainage / methods*
  • Female
  • Hemorrhage / etiology
  • Hemorrhage / prevention & control*
  • Hemorrhage / therapy
  • Humans
  • Injections, Intra-Articular
  • Knee Joint / surgery
  • Male
  • Middle Aged
  • Osteoarthritis, Knee / surgery
  • Postoperative Hemorrhage / prevention & control
  • Postoperative Hemorrhage / therapy
  • Retrospective Studies
  • Tranexamic Acid / administration & dosage*

Substances

  • Antifibrinolytic Agents
  • Tranexamic Acid