Study on the corrosion resistance and anti-infection of modified magnesium alloy

Biomed Mater Eng. 2017;28(4):339-345. doi: 10.3233/BME-171681.

Abstract

In this paper, a low-cost and multifunctional hydroxyapatite (HA)/pefloxacin (PFLX) drug eluting layer is coated on magnesium (Mg) alloy through a simple hydrothermal and dip process. The drug PFLX could provide effective prevention for bone infection and inflammation due to its broad-spectrum antibacterial property. And HA would promote the growth of new bone and further improve the biocompatibility of implants. Besides, both PFLX and HA exhibits excellent corrosion protection for Mg alloy substrate. This coating is of great value for improving the application of Mg alloy as biomaterials.

Keywords: Magnesium alloy; anti-corrosion; anti-infection; biocompatibility; biomaterials.

MeSH terms

  • Alloys
  • Bone Diseases, Infectious / prevention & control*
  • Coated Materials, Biocompatible*
  • Corrosion
  • Durapatite / chemistry*
  • Humans
  • Magnesium / chemistry*
  • Materials Testing
  • Prosthesis-Related Infections / prevention & control*

Substances

  • Alloys
  • Coated Materials, Biocompatible
  • Durapatite
  • Magnesium