Optimization of Detection Accuracy of Closed-Loop Optical Voltage Sensors Based on Pockels Effect

Sensors (Basel). 2017 Jul 27;17(8):1723. doi: 10.3390/s17081723.

Abstract

The influence of optical parameters on the performance of closed-loop optical voltage sensors (OVSs) based on Pockels effect is analyzed and a control algorithm is proposed to suppress the nonlinearity caused by the unideal parameters of optical devices for optimizing the detection precision of OVSs. First, a quantified model of the feedback phase demonstrates how the optical parameters of optical devices (including light source, polarizer, 45° fusion point, Faraday rotator and half-wave plate) result in the nonlinearity of closed-loop OVSs. Then, the parameter indexes of different optical devices are put forward to instruct the manufacturing process of the optical system. Furthermore, a closed-loop control algorithm is investigated to improve the measurement accuracy of nonlinear OVSs considering the unideal parameters. The experiment results indicate that additional bias caused by undesirable optical parameters is obviously decreased so that the measurement accuracy of OVSs satisfies the demand of IEC60044-3 for 0.1 level measurement accuracy, which verifies the effectiveness and correctness of the methods for suppressing the impact of unideal optical parameters on OVSs.

Keywords: closed-loop detection; detection accuracy; optical voltage sensor.