Mitral Valve Repair for Pure Mitral Regurgitation Followed Years Later by Mitral Valve Replacement for Mitral Stenosis

Am J Cardiol. 2017 Jul 1;120(1):160-166. doi: 10.1016/j.amjcard.2017.03.242. Epub 2017 Apr 12.

Abstract

We describe herein 2 patients who developed severe mitral stenosis (MS) approximately two decades after a mitral valve repair operation for pure mitral regurgitation (MR) secondary to mitral valve prolapse. This report's purpose is to point out that use of a circumferential mitral annular ring during the repair has the potential to produce a transmitral pressure gradient just like that occurring after mitral valve replacement utilizing a mechanical prosthesis or a bioprosthesis in the mitral position.