Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80 kV and iterative reconstruction algorithm using different concentration contrast media

J Med Imaging Radiat Oncol. 2017 Oct;61(5):614-621. doi: 10.1111/1754-9485.12608. Epub 2017 Mar 27.

Abstract

Introduction: Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol.

Methods: Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups.

Results: No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV.

Conclusions: Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols.

Keywords: CT angiography; ECG gated scan protocols, contrast agents; dose reduction; thoracic aorta.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Aorta, Thoracic / diagnostic imaging*
  • Aortic Diseases / diagnostic imaging*
  • Cardiac-Gated Imaging Techniques
  • Computed Tomography Angiography / methods*
  • Contrast Media / administration & dosage*
  • Female
  • Humans
  • Iopamidol / administration & dosage
  • Iopamidol / analogs & derivatives
  • Male
  • Middle Aged
  • Radiation Dosage*
  • Signal-To-Noise Ratio
  • Triiodobenzoic Acids / administration & dosage

Substances

  • Contrast Media
  • Triiodobenzoic Acids
  • iomeprol
  • iodixanol
  • Iopamidol