Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure: Rationale and Design of the Randomized Trial to REDUCE Elevated Left Atrial Pressure in Heart Failure (REDUCE LAP-HF I)

Circ Heart Fail. 2016 Jul;9(7):e003025. doi: 10.1161/CIRCHEARTFAILURE.116.003025.

Abstract

Heart failure with preserved ejection fraction (HFpEF), a major public health problem with high morbidity and mortality rates, remains difficult to manage because of a lack of effective treatment options. Although HFpEF is a heterogeneous clinical syndrome, elevated left atrial pressure-either at rest or with exertion-is a common factor among all forms of HFpEF and one of the primary reasons for dyspnea and exercise intolerance in these patients. On the basis of clinical experience with congenital interatrial shunts in mitral stenosis, it has been hypothesized that the creation of a left-to-right interatrial shunt to decompress the left atrium (without compromising left ventricular filling or forward cardiac output) is a rational, nonpharmacological strategy for alleviating symptoms in patients with HFpEF. A novel transcatheter interatrial shunt device has been developed and evaluated in patients with HFpEF in single-arm, nonblinded clinical trials. These studies have demonstrated the safety and potential efficacy of the device. However, a randomized, placebo-controlled evaluation of the device is required to further evaluate its safety and efficacy in patients with HFpEF. In this article, we give the rationale for a therapeutic transcatheter interatrial shunt device in HFpEF, and we describe the design of REDUCE Elevated Left Atrial Pressure in Heart Failure (REDUCE LAP-HF I), the first randomized controlled trial of a device-based therapy to reduce left atrial pressure in HFpEF.

Clinical trial registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02600234.

Keywords: atrial septum; cardiac output; heart failure; randomized controlled trial.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Atrial Function, Left*
  • Atrial Pressure*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Clinical Protocols
  • Europe
  • Heart Failure / diagnosis
  • Heart Failure / physiopathology
  • Heart Failure / therapy*
  • Heart-Assist Devices*
  • Humans
  • Prospective Studies
  • Prosthesis Design
  • Recovery of Function
  • Research Design
  • Single-Blind Method
  • Stroke Volume
  • Time Factors
  • Treatment Outcome
  • United States
  • Ventricular Function, Left

Associated data