MACULAR BUCKLING USING A THREE-ARMED SILICONE CAPSULE FOR FOVEOSCHISIS ASSOCIATED WITH HIGH MYOPIA

Retina. 2016 Oct;36(10):1919-26. doi: 10.1097/IAE.0000000000001014.

Abstract

Purpose: To investigate the safety and efficacy of a novel macular buckling technique on foveoschisis in highly myopic eyes.

Methods: Highly myopic eyes with foveoschisis, posterior staphyloma, and axial length greater than 26.5 mm, but without a full-thickness macular hole, were included. Macular buckling was performed in the included eyes using a three-armed adjustable silicon capsule.

Results: Eight eyes from eight patients (five women) were enrolled in this study. The mean follow-up period was 11.6 (range 9-14) months. After surgery, the best-corrected visual acuity was improved in 7/8 (87.5%) eyes, optical coherence tomography imaging showed gradual anatomic improvement of macula over time. The final best-corrected visual acuity gained 21.5 early treatment diabetes retinopathy study letters from baseline on average (P = 0.014). Postoperatively, the most common complications were transiently elevated intraocular pressure (62.5%) and asymptomatic abduction limitation (100%), and the most serious complication was hemorrhagic choroidal detachment (25%).

Conclusion: Macular buckling with a three-armed adjustable silicone capsule resulted in anatomic and visual improvement in eyes with myopic foveoschisis.

MeSH terms

  • Adult
  • Axial Length, Eye / pathology
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myopia, Degenerative / complications
  • Myopia, Degenerative / physiopathology
  • Myopia, Degenerative / surgery*
  • Postoperative Complications
  • Prospective Studies
  • Retinoschisis / etiology
  • Retinoschisis / physiopathology
  • Retinoschisis / surgery*
  • Scleral Buckling / instrumentation*
  • Scleral Buckling / methods
  • Silicone Elastomers*
  • Tomography, Optical Coherence
  • Visual Acuity / physiology
  • Vitrectomy

Substances

  • Silicone Elastomers