Enhancement of capillary electrochromatographic separation performance by conductive polymer in a layer-by-layer fabricated graphene stationary phase

J Chromatogr A. 2014 Apr 25:1339:192-9. doi: 10.1016/j.chroma.2014.02.083. Epub 2014 Mar 5.

Abstract

In this work, we fabricated a novel graphene-based capillary column for open-tubular capillary electrochromatography (OT-CEC) by a layer-by-layer strategy. To immobilize graphene onto the inner surface of silica capillary, a bio-inspired method was first used to functionalize the capillary surface with a layer of polydopamine (PDA). Graphene oxide (GO) was then introduced and can covalently react with polydopamine, realizing immobilization of graphene as a result. To enhance the modification efficiency of polydopamine, a conductive polymer, polyaniline (PANI) was introduced to be a sub-layer; polydopamine was then introduced following with GO, to generate a multilayer GO-PDA-PANI@capillary. Interestingly, separation efficiency of the graphene-based capillary was enhanced significantly by using conductive PANI as a sub-layer. The morphology of different layers modified on the capillary column was characterized by scanning electron microscopy (SEM). The electroosmotic flow (EOF) characteristics of capillaries modified with different layers were also investigated by varying the pH value of mobile phase. GO-PDA-PANI@capillary showed good separation efficiency towards alkylbenzenes by OT-CEC mode, with theoretic plate numbers up to 133,918 for benzene. The separation was found to follow a reversed-phase chromatographic retention mechanism. Repeatability of the GO-PDA-PANI@capillary was studied, with relative standard deviations for intra-day and inter-day runs less than 2.89%, and column-to-column runs less than 6.17%. The separation performance of GO-PDA-PANI@capillary was also compared with that of the reported graphene modified capillary.

Keywords: Capillary electrocheromatography; Conductive polymer; Graphene; Layer-by-layer; Polydopamine.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aniline Compounds / chemistry
  • Capillary Electrochromatography / instrumentation
  • Capillary Electrochromatography / methods*
  • Chromatography, Reverse-Phase
  • Electroosmosis
  • Graphite / chemistry*
  • Hydrogen-Ion Concentration
  • Indoles / chemistry
  • Polymers / chemistry
  • Reproducibility of Results
  • Silicon Dioxide / chemistry

Substances

  • Aniline Compounds
  • Indoles
  • Polymers
  • polyaniline
  • polydopamine
  • Silicon Dioxide
  • Graphite