Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
BMC Sports Sci Med Rehabil. 2014 Feb 25;6(1):10. doi: 10.1186/2052-1847-6-10.

Reference values for isometric muscle force among workers for the Netherlands: a comparison of reference values.

Author information

  • 1Research and Innovation Group in Health Care and Nursing, Hanze University of Applied Sciences, Eysoniusplein 18 9714 CE, Groningen, The Netherlands. k.w.douma@pl.hanze.nl.

Abstract

BACKGROUND:

Muscle force is important for daily life and sports and can be measured with a handheld dynamometer. Reference values are employed to quantify a subject's muscle force. It is not unambiguous whether reference values can be generalized to other populations. Objectives in this study were; first to confirm the reliability of the utilization of hand-held dynamometers for isometric strength measurement; second to determine reference values for a population of Dutch workers; third to compare these values with those of a USA population.

METHODS:

462 Healthy working subjects (259 male, 203 female) were included in this study. Their age ranged from 20 to 60 years with a mean (sd) of 41 (11) years. Muscle force values from elbow flexion and extension, knee flexion and extension, and shoulder abduction were measured with the break method using a MicroFet 2 hand-held dynamometer. Reliability was analyzed by calculating ICC's and limits of agreement. Muscle force expressed in Newton, means, and confidence intervals were determined for males and females in age groups ranging from twenty to sixty years old. Regression equations and explained variances were calculated from weight, height, age, and gender. The mean values and 95% CI were compared to the results from other studies.

RESULTS:

Reliability was good; the ICC ranged between 0.83 to 0.94. The explained variance ranged from 0.25 to 0.51. Comparison of data for the Dutch population mean muscle force values with those from the USA revealed important differences between muscle force reference values for the American and Dutch populations.

CONCLUSIONS:

Muscle force measurements demonstrate a sound reliability. Reference values and regressions equations are made available for the Dutch population. Comparison with other studies indicates that reference values differ between countries.

PMID:
24568140
[PubMed]
PMCID:
PMC3996060
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for PubMed Central
    Loading ...
    Write to the Help Desk