To determine the effect of gross tumor volume of the primary (GTV-P) and nodal (GTV-N) disease on planned radiation dose to the brachial plexus (BP) in head and neck intensity-modulated radiotherapy (IMRT). Overall, 75 patients underwent definitive IMRT to a median total dose of 69.96Gy in 33 fractions. The right BP and left BP were prospectively contoured as separate organs at risk. The GTV was related to BP dose using the unpaired t-test. Receiver operating characteristics curves were constructed to determine optimized volumetric thresholds of GTV-P and GTV-N corresponding to a maximum BP dose cutoff of > 66Gy. Multivariate analyses were performed to account for factors associated with a higher maximal BP dose. A higher maximum BP dose (> 66 vs ≤ 66Gy) correlated with a greater mean GTV-P (79.5 vs 30.8cc; p = 0.001) and ipsilateral GTV-N (60.6 vs 19.8cc; p = 0.014). When dichotomized by the optimized nodal volume, patients with an ipsilateral GTV-N ≥ 4.9 vs < 4.9cc had a significant difference in maximum BP dose (64.2 vs 59.4Gy; p = 0.001). Multivariate analysis confirmed that an ipsilateral GTV-N ≥ 4.9cc was an independent predictor for the BP to receive a maximal dose of > 66Gy when adjusted individually for BP volume, GTV-P, the use of a low anterior neck field technique, total planned radiation dose, and tumor category. Although both the primary and the nodal tumor volumes affected the BP maximal dose, the ipsilateral nodal tumor volume (GTV-N ≥ 4.9cc) was an independent predictor for high maximal BP dose constraints in head and neck IMRT.

Copyright © 2014. Published by Elsevier Inc.

KEYWORDS:

Brachial plexus; Dose-volume histogram; Gross tumor volume; Head and neck cancer

[PubMed - indexed for MEDLINE]
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science Icon for PubMed Central
    Loading ...
    Write to the Help Desk