J Biomech. 2013 Jun 21;46(10):1767-71. doi: 10.1016/j.jbiomech.2013.04.001. Epub 2013 May 9.

Validation of a finite element model of the human elbow for determining cartilage contact mechanics.

Author information

  • 1Bioengineering Research Laboratory, The Hand and Upper Limb Centre, St. Joseph's Health Care London, London, Ontario, Canada. willing.ryan@gmail.com

Abstract

It is important to study joint contact mechanics to better understand the processes which lead to cartilage degradation. The purpose of this study was to develop and validate a finite element (FE) model of a human elbow capable of predicting joint contact area and stress. A cylindrical constrained elbow joint loading apparatus was used to measure the cartilage compression and contact area for a single cadaveric specimen. A computer model of the same joint was created based on computed tomography images of the specimen, and the same loading was simulated using FE contact analysis. The model-predicted joint compression and contact area corresponded closely with experiment-measured results (differences of -4.9% and +9.6%). A sensitivity analysis showed that the model results were sensitive to cartilage and bone material properties, as well as the cartilage thickness distribution. The results of this study underline the importance of using accurate material properties and physiological cartilage thickness distributions when simulating cartilage contact mechanics.

Copyright © 2013 Elsevier Ltd. All rights reserved.

PMID:
23664239
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk