Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
Front Physiol. 2012 May 23;3:147. doi: 10.3389/fphys.2012.00147. eCollection 2012.

Amplitude Changes during Ventricular Fibrillation: A Mechanistic Insight.

Author information

  • 1Institute of Cardiovascular and Medical Sciences, University of Glasgow Glasgow, UK.

Abstract

INTRODUCTION:

Clinically in ventricular fibrillation (VF), ECG amplitude, and frequency decrease as ischemia progresses and predict defibrillation success. In vitro ECG amplitude declines without ischemia, independent of VF frequencies. This study examines the contribution of cellular electrical activity and global organization to ECG amplitude changes during VF.

METHODS AND RESULTS:

Rabbit hearts were Langendorff-perfused (40 mL/min, Tyrode's solution) and loaded with RH237. During VF, ECG, and epicardial optical action potentials were recorded (photodiode array; 256 sites, 15 mm × 15 mm). After 60 s of VF, perfusion was either maintained, global ischemia produced by low-flow (6 mL/min), or solution [K(+)](o) raised to 8 mM. Peak-to-peak amplitude was determined for all signals. During VF, in control, ECG amplitude decreased to a steady-state (∼57% baseline), whereas in low-flow steady-state was not reached with the amplitude continuing to fall to 33% of baseline by 600 s. Optically, LV amplitude declined more than RV, reaching significance in control (LV vs. RV; 33 ± 5 vs. 63 ± 8%, p < 0.01). During VF in 8 mM [K(+)](o), amplitude changes were more complex; ECG amplitude increased with time (105 ± 13%), whilst LV amplitude decreased (60 ± 15%, p < 0.001). Microelectrode studies showed amplitude reduction in control and 8 mM [K(+)](o) (to ∼79 and ∼93% baseline, respectively). Evaluation of electrical coordination by cross-correlation of optical signals showed as VF progressed coordination reduced in control (baseline 0.36 ± 0.02 to 0.28 ± 0.003, p < 0.01), maintained in low-flow (0.41 ± 0.03 to 0.37 ± 0.005, p = NS) and increased in 8 mM [K(+)](o) (0.36 ± 0.02 to 0.53 ± 0.08, p < 0.05).

CONCLUSION:

ECG amplitude decline in VF is due to a combination of decreased systolic activation at the cellular level and increased desynchronization of inter-cellular electrical activity.

KEYWORDS:

ECG; floating microelectrode; ischemia; optical mapping; ventricular fibrillation

PMID:
22654763
[PubMed]
PMCID:
PMC3358710
Free PMC Article

Images from this publication.See all images (8)Free text

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for Frontiers Media SA Icon for PubMed Central
    Loading ...
    Write to the Help Desk