Display Settings:

Format

Send to:

Choose Destination
We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
    J Proteome Res. 2012 May 10. [Epub ahead of print]

    Optimized Fast and Sensitive Acquisition Methods for Shotgun Proteomics on a Quadrupole Orbitrap Mass Spectrometer.

    Source

    Department of Proteomics, Novo Nordisk Foundation Center for Protein Research, Faculty of Health Sciences, University of Copenhagen , Blegdamsvej 3b, DK-2200 Copenhagen N, Denmark.

    Abstract

    Advances in proteomics are continually driven by the introduction of new mass spectrometric instrumentation with improved performances. The recently introduced quadrupole Orbitrap (Q Exactive) tandem mass spectrometer allows fast acquisition of high-resolution higher-energy collisional dissociation (HCD) tandem mass spectra due to the parallel mode of operation, where the generation, filling, and storage of fragment ions can be performed while simultaneously measuring another ion packet in the Orbitrap mass analyzer. In this study, data-dependent acquisition methods for "fast" or "sensitive" scanning were optimized and assessed by comparing stable isotope labeled yeast proteome coverage. We discovered that speed was the most important parameter for sample loads above 125 ng, where a 95 ms HCD scanning method allowed for identification and quantification of more than 2000 yeast proteins from 1 h of analysis time. At sample loads below 125 ng, a 156 ms HCD acquisition method improved the sensitivity, mass accuracy, and quality of data and enabled us to identify 30% more proteins and peptides than the faster scanning method. A similar effect was observed when the LC gradient was extended to 2 or 3 h for the analysis of complex mammalian whole cell lysates. Using a 3 h LC gradient, the sensitive method enabled identification of more than 4000 proteins from 1 μg of tryptic HeLa digest, which was almost 200 more identifications compared to the faster scanning method. Our results demonstrate that peptide identification on a quadrupole Orbitrap is dependent on sample amounts, acquisition speed, and data quality, which emphasizes the need for acquisition methods tailored for different sample loads and analytical preferences.

    PMID:
    22537090
    [PubMed - as supplied by publisher]

      Supplemental Content

      Icon for American Chemical Society

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk