Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
AJNR Am J Neuroradiol. 2012 Aug;33(7):1337-42. doi: 10.3174/ajnr.A2980. Epub 2012 Mar 8.

Clinical assessment of standard and generalized autocalibrating partially parallel acquisition diffusion imaging: effects of reduction factor and spatial resolution.

Author information

  • 1Department of Radiology, Stanford University, Stanford, California, USA. drjalal@uw.edu

Abstract

BACKGROUND AND PURPOSE:

PI improves routine EPI-based DWI by enabling higher spatial resolution and reducing geometric distortion, though it remains unclear which of these is most important. We evaluated the relative contribution of these factors and assessed their ability to increase lesion conspicuity and diagnostic confidence by using a GRAPPA technique.

MATERIALS AND METHODS:

Four separate DWI scans were obtained at 1.5T in 48 patients with independent variation of in-plane spatial resolution (1.88 mm(2) versus 1.25 mm(2)) and/or reduction factor (R = 1 versus R = 3). A neuroradiologist with access to clinical history and additional imaging sequences provided a reference standard diagnosis for each case. Three blinded neuroradiologists assessed scans for abnormalities and also evaluated multiple imaging-quality metrics by using a 5-point ordinal scale. Logistic regression was used to determine the impact of each factor on subjective image quality and confidence.

RESULTS:

Reference standard diagnoses in the patient cohort were acute ischemic stroke (n = 30), ischemic stroke with hemorrhagic conversion (n = 4), intraparenchymal hemorrhage (n = 9), or no acute lesion (n = 5). While readers preferred both a higher reduction factor and a higher spatial resolution, the largest effect was due to an increased reduction factor (odds ratio, 47 ± 16). Small lesions were more confidently discriminated from artifacts on R = 3 images. The diagnosis changed in 5 of 48 scans, always toward the reference standard reading and exclusively for posterior fossa lesions.

CONCLUSIONS:

PI improves DWI primarily by reducing geometric distortion rather than by increasing spatial resolution. This outcome leads to a more accurate and confident diagnosis of small lesions.

PMID:
22403781
[PubMed - indexed for MEDLINE]
PMCID:
PMC3985834
Free PMC Article

Images from this publication.See all images (6)Free text

Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Fig 6
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for HighWire Icon for PubMed Central Icon for FindIt@Stanford
    Loading ...
    Write to the Help Desk