Display Settings:

Format

Send to:

Choose Destination
    J Clin Microbiol. 2012 Apr;50(4):1281-4. Epub 2012 Jan 18.

    Comparison of three assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath Pap samples and the role of pre- and postcytology testing.

    Source

    St. Joseph’s Healthcare/McMaster University, Hamilton, ON, Canada. chernesk@mcmaster.ca

    Abstract

    Chlamydia trachomatis and Neisseria gonorrhoeae are common causes of sexually transmitted infections, and there is interest in screening SurePath liquid-based Pap (L-Pap) samples with Aptima Combo 2 (AC2), Amplicor (AMP), and ProbeTec ET (PT) assays. SurePath L-Pap samples and a cervical swab (CS) were collected from 394 women attending health clinics in Hamilton and Toronto, ON, Canada. L-Pap samples were tested with the three assays prior to being processed for cytology, and the CS sample was tested with AC2. The prevalence of C. trachomatis was 8.9%, and that of N. gonorrhoeae was 1.5%. By using the positives from CS testing, as well as CS negatives corresponding to L-Pap samples that tested positive in 2 of 3 assays, the sensitivities of AC2, AMP, and PT for C. trachomatis in precytology samples were calculated to be 97.1% (34 of 35 positive samples were detected), 91.4% (32 of 35 were detected), and 77.1% (27 of 35 were detected), respectively. Six women were infected with N. gonorrhoeae. After cytology processing, the results of testing the remaining liquid in the L-Pap vial and the cell-enriched fraction for C. trachomatis by AC2 showed positive agreements of 98.9% (kappa [k], 0.93) and 98.7% (k, 0.92), respectively, with the results of testing precytology L-Pap samples. Although all testing showed high specificity, testing for C. trachomatis by AC2 was significantly more sensitive than testing by PT for SurePath samples (P = 0.02). Newer versions of AMP (Cobas 4800) and PT (Q(x) with XTR technology) need published evaluations for detecting C. trachomatis and N. gonorrhoeae in L-Pap samples. C. trachomatis testing can be performed with similar results on pre- and postcytology SurePath samples.

    PMID:
    22259215
    [PubMed - in process]
    PMCID:
    PMC3318522
    [Available on 2012/10/1]

      Supplemental Content

      Icon for HighWire Press

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk